10A |
|
5A |
|
2.0ms | 3.0ms |
Continuous Transient Operation |
Pulse
Switch to value B upon receiving one trigger signal , after taking the pulse time(TWD) of value B, the load will return to Value A .
10A |
|
|
5A | TWD | TWD |
| 10ms | 10ms |
| TRIG | TRIG |
| Pulsed Transient Operation |
Trigger Mode
Switches the state between value A and value B once trigger signal is received.
10A |
|
5A |
|
TRG | TRG |
Toggled Transient Operation |
List Operation
List mode lets you generate complex sequences of input changes with rapid, precise timing, which may be synchronized with internal or external signals. List operation can be changed by editing every step value and time in list operation. The parameter of list operation include the group file name, input step setting (the max steps is 1000 steps),time of one step
(1mS~6000mS)and setting value of one step. In CC mode, dwell time range is 1mS to 6S, which also have an associated
value. Note that lists data can only be saved in total 1000 steps memory of 4 situations.
15