Input On/Off

Electronic load's input can be toggled on/off at the front panel. Turning the input off (zero current) does not affect the programmed settings. The input will return to the previously programmed values when the input is turned on again.

NOTE

The Input On/Off command supersedes the mode commands and Short Test

On/Off command.

Operation Range

Work in the range of Rated Current, Rated voltage and Rated Power, The figure is as following:

Rated voltage

INPUT VOLTAGE V

Rated power

Operation mode change state

Rated voltage

INPUT VOLTAGE V

C

Input current I Rated current

Software Power Limit

Software Current Limit

A

Input current I Rated current

Protection Features

This Electronic Load includes the following protection features:

Over Voltage

If input voltage exceeds the voltage limit, Load will turn OFF the input and a buzzer turns on. VFD displays the following:

OVER VOLTAGE

Over Current