19

TRIG:

A TTL-compatible input that responds to external edge trigger signal. A trigger applied to this input can be
used to change settings (voltage, current, resistance, etc.), toggle between settings in transient-toggle mode, or
generate a pulse in transient-pulse mode.
You must set the remote sense mode in the menu before using the remote sense function.

Action:

1 Press
Shift
+
Menu
key into the menu
2 VFD displays >CONFIG, press
Enter
key to confirm
3 Press key to choose>REMOTE SENSE, press
Enter
key to confirm
4 Press /to choose>ON, press
Enter
key to confirm. And the remote sense function has been set.

Wiring diagram for remote sense

Input port in front panel
Sense port in rear panel
UUT
+
-
+
-
+
-

Saving and Recalling Settings
The electronic load has internal registers in which settings (mode, current, voltage, resistance, transient level, etc.) are
stored. Users could use
Shift
+
Store
and
Shift
+
Recall
to save and recall the relative data as
following:
CC value /CW value /CR value /CV value
Transition current A value /Transition current B value /Transition voltage A value /Transition voltage B value /
Transition power A value /Transition power B value /Transition Resistance A value /Transition Resistance B value
Current A pulse width time/ Current B pulse width time/Voltage A pulse width time/ Voltage B pulse width time /Power
A pulse width time/Power B pulse width time /Resistance A pulse width time /Resistance B width time
Transition current testing mode/Transition voltage testing mode/Transition power testing mode /Transition resistance
testing mode
Max current value / Max voltage value / Max power value

Example:

1) Press
I-setI-set
, set a value of current or voltage, press
Enter
to confirm.
2) Press
Shift
+
Store
set a store code at random, press
Enter
to confirm.
3) Press
Shift
+
Recall
, set the store code that you set before, press
Enter
to confirm, then yo u can get
the number stored.