In Case of Trouble

Should the power-on self test of the Electronic Load fail, you may try the following: When turning on the power, make sure the power cord to the unit is plugged in and the power switch is in the on position.

1)Check the power voltage setting.

Work voltage of load have two type 110V or 220V , Please make sure it is right voltage accordance to the voltage in your area. You could change the voltage setting through dial the switch in the rear panel.

2)Check the fuse.

If fuse is blown, please replace it according to the following specification.

Model

Fuse specification

Fuse specification

 

(110VAC)

(220VAC)

8510

T0.5A

250V

T0.3A

250V

3) Location of Fuse

Fuse

Front Panel Operation

Display

16-character fluorescent display for showing measurements and programmed values.

Front Panel Display

Indicators for operating modes and status conditions:

OFF

power off

Trigger

Indicates that the electronic load is waiting an

 

 

 

initiate and trigger to occur.

 

 

 

 

CC

The selected input channel is in the

Sense

Indicates that the electronic load is in sense

 

constant current (CC) mode.

 

state

 

 

 

 

CV

The selected input channel is in the

Error

A errors have occurred

 

constant voltage (CV) mode.

 

 

 

 

 

 

CW

The selected input channel is in the

Link

In the communication state

 

constant power (CW) mode.

 

 

 

 

 

 