8510 instruction manual
Please, tick the box below to download manual:
Contents
Main
INSTRUCTION MANUAL
Instruction Manual for
Model 8510 PROGRAMMABLE DC ELECTRONIC LOAD
TABLE OF CONTENTS
Warranty Information
Certification
Assistance
Safety Summary
Environmental Conditions
Safety Symbols
WARNING
CAUTION
Quick Reference
The Front Panel
2 3 4
5
The Rear Panel
Front Panel Display
Immediate Action Keys
Front Panel Menus
Key Pad
Menu Operation
Page
ON
OFF<DEFAULT>
TIMER SET
EXIT EXIT
General Information
Document Orientation
Options
Getting Started Map
Task Where to find information
Description
Features and Capabilities
Front Panel Controls
Remote Programming
Operating Modes
Constant Current
CC
Mode
Transient Operation
Continuous
10A 5A Continuous Transient Operation
2.0ms 3.0ms
Pulse
List Operation
GROUP Total = 1000 steps 1 1000 steps 2 500
0000
Trigger
Triggered Operation
Input Control
Short On/Off
Shift
Short
Protection Features
Over Voltage
Over Power
Reverse Voltage
_
Remote Sense Function and Trig ger Function
+
TRIG:
Action:
UUT
Saving and Recalling Settings
Store
Recall
Example:
Battery Testing
Capability test
Operation:
I-setI-set
Von/Voff Operation
Action for set Von/Voff value:
Installation
Inspection
Dimension :
Description
Item
Bench Operation
CAUTION
Input Connections
Power Cord
WARNING
Turn-On Checkout
Introduction
Checkout Procedure
.
Procedure Display Explanation
Front Panel Operation
Display
Front Panel Display
Example
I-set (set up a constant current from 0 to Max current )
Procedure Operation details VFD display
STEP 1
CURRENT=0.000A
P-set (set up a constant power from 0 to Max power)
Procedure Operation details VFD display Step 1
P-set
POWER =0.000W Step 2
POWER=*.***W Step 3
Transition Testing Operation
29
Transition Parameter Setting
+
CONTINOUS
,
Toggled Transient Operation
Toggled Transient Operation
Steps
Trigger
Shift
List Operation
Trigger
List sequence
Steps
Quick Recall Function
Automatic Testing Function of Electronic Load
Edit the Testing File
Page
Taking out the Testing File Rapidly
Automatic Testing
I-setI-set
Setting the Resolution a nd number of decimal points
35
>CONFIG
Specifications
Parameter 8510
Range Accuracy Resolution
36
NOTE:
IT-E132 USB Communication cable
PC Load
Remote Operation Mode
2 Communication between electronic load and PC
3. Frame Format
Frame length is 26 b ytes. Details as following:
AAH Address Command 425bytes are information content Parity code
Page
4. Communication Protocol
20H
1. Selecting the Remote control mode
2. Selecting the input on/off state
21H
24H/25H
4. Setting / Reading the max input current .
22H/23H
0X00
28H/29H
0X0d
0X00030d40
0X30
0X00
5. Setting / Reading max input power
6. Selecting / Reading CC/CV/CW/CR operation mode of Electronic load.
7. Setting / Reading CC mode current value
2AH/2BH
2EH/2FH
0X3E
0XB0
10. Setting / Reading CR mode resistance value
30H/31H
32H/33H
11. Setting /Reading CC mode transient current and timer parameter.
12. Setting /Reading CV mode transient voltage and timer parameter.
34H/35H
38H/39H
36H/37H
13. Setting /Reading CW mode transient watt and timer parameter
3AH/3BH
Selecting /Reading the list operation mode (CC/CV/CW/CR)
15
16. Setting /Reading the list repeat mode. (3CH/3DH)
17. Setting / Reading the number of list steps. (3EH/3FH)
18. Setting / Reading one of the steps current and time values. (40H/41H)
19. Setting / Reading one of the steps voltage and time values. (42H/43H)
20. Setting / Reading one of the steps power and time values. (44H/45H)
21. Setting / Reading one of the steps power and time values. (46H/47H)
22. Setting / Reading List file name (48H/49H)
23. Selection / Reading the memory space mode for storing list steps. (4AH/4BH)
24. Save / Get list file in appointed area.. (4CH/4DH)
4EH/4FH
25. Setting / Reading min voltage value in battery testing mode.
27. Disable / Enable timer of FOR LOAD ON (52H); Reading timer state of FOR LOAD ON (53H)
28. Setting communication address (54H)
29. Enable/Disable LOCAL control mode. (55H)
30. Enable / Disable remote sense mode. (56H)
Reading the state of remote sense mode. (57H)
32. Sending a trigger signal to trigging the electronic load. (5AH)
33. Saving / Recall users setting value in appointed memory area for recall. (5BH/5CH)
34. Selecting / Getting FIXED/SHORT/TRAN/LIST/ BATTERY function mode. (5DH/5EH)
35. Reading input vol tage, current, power and relative state. (5FH)
BIT Signal Meaning
36. Enter the calibration mode
60H
37. Getting the calibration mode state
61H
63H
39. Sending the actual input voltage to calibration program
62H
40. Calibrate current value
64H
67H/68H
43. Setting / Reading calibration information
66H
44. Restore the factory default calibration data
For example
6AH
45. Reading products model, series number and version information
46. Reading information in bar code (6BH)
Page
55
Service Information
Non-Warranty Servi ce:
Warranty Service:
Limited One-Year Warranty
Declaration of CE Conformity
according to EEC directives and NF EN 45014 norm
22820 Savi Ranch Parkway Yorba Linda, CA 92887