Transition Parameter Setting

Users could press Shift

+ S-Tranto set the transition parameter.

 

Shift + S-Tran

 

LEVEL A = *****

Setup value A

 

Enter

 

WIDTH A = ******

Setup time width of value A

 

Enter

 

LEVEL B=*****

Setup value B

 

Enter

 

WIDTH B= *****

Setup time width of value B

 

Enter

 

CONTINUOUS

Choose one of the three transition

 

 

 

PULSE

modes

 

 

 

TOGGLED

 

 

Enter

 

 

Finish transition setting

 

 

 

 

 

Continuous Transient Operation

In this mode, electronic load will generates a repetitive pulse stream that toggles between two load levels. ; Load could switch the state between two setting value (value A and value B).

In this following example, assume that the CC mode is active; the applicable transient operation parameters have been set as follows.

For example:

Continuous mode, current level A =5A, width = 2mS. Current level B =10A, width = 3ms. Testing machine input voltage is 12V.

10A

 

5A

 

2.0ms

3.0ms

Continuous Transient Operation

Action

1.

Select the operation mode (CC,CV,CR or CP), and set a proper value, press On/Off to turn off the load input.

2.

Press

Shift

+

S-Tran

, set LEVEL A=5A, press Enter

, set

WIDTH A=3mS, press Enter , set

 

LEVER B=10A,

press Enter , set WIDTH B=2mS, press

Enter

to confirm.

3.Transition mode now is CONTINOUS, press Enter to confirm.

 

4.

Press

Shift

+

Tran

to activate the transient mode.

 

 

5.

Press

Shift

+

Tran

again to stop the transient operation.

 

6. Press On/Off , the input of load is powered on.

Pulse Transient Operation

In this mode, generates a transient pulse of programmable width when pulsed transient operation is in effect.