IT-E151 Rack mounts kit: for installation of one or two 8500 series load on the 19 inch rack.

IT-E131 isolated communication cable: This cable converts the electronic load’s serial port (TTL 5V level) to PC RS232 interface.

IT-E132 isolated communication cable: This cable converts the electronic load’s serial port (TTL 5V level) to PC USB interface.

Accessories

Power cord

User’s manual

Software CD-Rom

Calibration test report

IT-E132 isolated communication cable

Description

The 8500 series electronic loads are used for the design, manufacturing, and evaluation of DC power supplies, batteries, and power components. The electronic load contains a processor, serial port connector, front-panel keypad and VFD, and other circuits common to the other entire load module.

The model 8510 serial electronic load operates in constant current (CC) mode, constant voltage (CV) mode, or constant resistance (CR) mode and constant power (CW) Mode.

Features and Capabilities

High accuracy and high resolution

Capable to work with constant current (CC), constant voltage (CV), constant resistance (CR) mode and constant power (CW) operation.

Serial port interface-DB9-RS232 port.

Triggered input and measurement functions.

Built-in pulse generator for continuous, pulsed, and toggled transient mode operation.

Over voltage, over current, overpower, and over temperature protection.

Electronic load calibrate by Software.

Fan speed control by temperature.

VFD display

Short circuit test

Battery testing function.

Front Panel Controls

The front panel has keyboard controls for setting the input voltage, current and resistance. The panel display provides digital readouts of a number of functions including the inputs. The VFD display indicates the operating status of the electronic load.

12

Page 12
Image 12
B&K 8510 instruction manual Description, Features and Capabilities, Front Panel Controls, Accessories