Zone Monitor

User Code Level: Master and Standard.

Function: Allows the system to monitor selected disarmed zones (doors, windows, or motion detectors) and sound a tone at the keypad as well as display their name on the keypad display as they're faulted.

This is an ideal feature for monitoring door zones to tell when someone comes in or goes out.

You can place any combination of disarmed zones in Zone Monitor but only the most recent zone faulted is displayed. The displayed zone name clears automatically after a short time or when the zone is armed.

Zone Monitor does not function while the system is armed but a zone placed into it will still be there when the system is disarmed.

Using Zone Monitor as part of your weekly system test: After using the System Test function (see page 14), place all perimeter and interior zones in Zone Monitor. Starting at the front door, go around and open and then close each door and window. You should hear the keypad beep each time. The keypad will also display the name of each zone as its device is opened.

Once all protected doors and windows have been tested, walk in front of each motion detector. The keypad should beep to confirm their operation. If at any time during your weekly testing a device does not cause the keypad to beep, call the service department for assistance.

Using the Zone Monitor Function

1.Access the User Menu.

2.Press the COMMAND key until ZONE MONITOR? displays.

3.Press any one of the SELECT keys.

The keypad displays PERIM ALL NBR .

4.Select PERIM to place all disarmed perimeter zones into Zone Monitor.

4a. The keypad displays PERIM? ADD RMV.

4b. Select ADD to add all perimeter zones to Zone Monitor. 4c. Select RMV to remove all perimeter zones.

5.Select ALL to place all disarmed perimeter and interior zones into Zone Monitor.

5a. The keypad displays ALL? ADD RMV.

5b. Select ADD to add all disarmed zones to Zone Monitor. 5c. Select RMV to remove all disarmed zones.

6.Select NBR to enter a specific zone number for zone monitor.

7.If NBR is selected, the keypad displays ZONE : - ADD RMV. 7a. Enter any zone number and select ADD to add this zone.

7b. Enter any zone number and select RMV to remove this zone.

8.The zone number automatically disappears and a new zone number can then be entered in step 7a.