DMP Electronics XR6 User Codes, Using the System Test Function, 10 3812Master, User Menu

Models: XR6 XR10

1 28
Download 28 pages 40.09 Kb
Page 18
Image 18
System Test

System Test

User Code Level: Master or Standard.

Function: System Test is used to test the battery, alarm bell or siren, and communication to a central station. The System Test function begins automatically as soon as you select it.

Using the System Test Function

1.Access the User Menu.

2.Press the COMMAND key until SYSTEM TEST? displays.

3.Press any one of the SELECT keys. The system test begins automatically and the keypad displays:

1)BELL SOUNDING during a two second bell test, then:

2)BATTERY - OKAY or BATTERY - TRBL to indicate the condition of the battery, then:

*3) TRANSMIT TEST and ATTEMPT NO : 1 during the transmit test, then:

4)TRANSMIT OKAY or TRANSMIT FAILED to show the results of the transmit test, then:

5)TEST END to indicate the System Test is complete.

6)You can end the transmit test by pressing the ARROW key.

* The transmit test does not operate on local systems.

Testing your system's burglary protection: The System Test function should be part of your weekly testing and should be followed by placing the interior and perimeter burglary devices in Zone Monitor mode. This allows you to open and then close each protected door and window while listening for the keypad to beep confirming its operation. See Zone Monitor.

User Codes

User Code Level: Master only.

Function: Allows you to add or delete a user from the system or change their security code or authority level.

There are three characteristics associated with each user code that define its capabilities within the system.

10 3812Master

User number

Security Code

Authority level

User Number - Your system supports twelve users. Each user is numbered from 1 to 12. This number identifies them to the system and is transmitted to the central station (if your system is monitored) when they arm or disarm the system.

Security Code - Users also have a 4-digit security code that they enter into the keypad when arming or disarming. This security code is kept secret from other users and is not transmitted to the central station when they arm or disarm.

A user enters only their security code when operating the system.

Authority Level - The user is also assigned a level of authority (Master or Standard) by the person administrating the system that determines the functions they can access.

The table to the right lists system functions users are allowed to access based on the authority level assigned to their codes at the time they’re added to the system.

14

User Menu

Page 18
Image 18
DMP Electronics XR6, XR10 manual User Codes, Using the System Test Function, 10 3812Master, User Menu