DP564 Multichannel Audio Decoder Appendix C: Specifications
C-3
Test Noise
Auto: Sequences wideband or band-limited pink noise through enabled channels at
two-second intervals
Manual: Feeds continuous noise to selected channel when unit is in Trim Level mode
Power Requirements
90 to 264 VAC, 50 to 60 Hz, auto-sensing, 40 W maximum; this unit is designed to
operate from a centrally switched power source
Dimensions and Weight
2-U rack-mount: 88 × 483 × 376 mm (3.5 × 19 × 14.8 inches)
Net: 4 kg (8.5 lbs)
Environmental Conditions
Operating: 0° to 50°C (32° to 122°F), natural convection cooling, 0 to 98% relative
humidity (non-condensing)
Non-operating: –20° to +70° C (–4° to +158°F)