IF THE WATER PURIFIER STOPS WORKING

Service and spare parts

Before calling service, use the trouble-shooting guide “If the water purifier stops working” to try to rectify the fault yourself. If service is called in to solve a problem that is in this list, there is a risk that you will be responsible for the cost. The same applies if you have used the appliance for a purpose other than that for which it is intended.

Note that electrical faults should always be rectified by a certified electrician.

Give the appliance’s product and serial numbers according to the data plate (see fig. A). The plate is located on the back of the water purifier.

You can record these details here:

PROD.NO ............................................................

SER.NO ................................................................

Purchase date ........................................................

A

TECHNICAL DATA

Data

Dimensions:

 

 

- height

340 mm

 

- depth

140 mm

 

- width

290 mm

 

Weight:

 

 

- on delivery

3.0 kg

 

- filled with water

3.7 kg

 

Capacity:

3.8 (±0.8) litres/minute

0.84 (±0.18) gpm (UK)

Inlet pressure:

0.3-5 bar (30-500 kPa)

5-72 PSI

Working temperature:

 

 

- ambient and water temperature

2 - 43 °C

 

Electrical data:

 

 

Connection

12-24 V DC

 

Low voltage protection

9 V

 

Resetting low voltage protection

10 V

 

Power consumption (excl. pump output):

 

 

- during purification

10 W

 

- during heating

12 W

 

- in standby

1 W

 

Fuse, slow blow

6.3 A

 

Pump current, max:

5 A

 

Requirements on feed water to water purifier

The tank must be filled with municipal water. In standing water (tank water) there is a risk of bacterial growth. The water purifier is intended to purify the tank water.

Turbidity

<

7.5 FNU

Chlorine

4 mg/litre

Organic content

<

1 mg/litre

14