Dometic CWP 5311 user manual Draining

Models: CWP 5311

1 117
Download 117 pages 32.35 Kb
Page 8
Image 8

MAINTENANCE

Draining

Storage below temperature 0°C (32°F) and maintenance requires that the purifier is emptied.

1. Check that the water from the drain hose is led out under the caravan.

2.Shut off the water purifier with the ON/OFF button.

3.Disconnect the power supply to the water purifier with the safety switch in the central electrical unit.

4.Press the Release button at the back of the purifier, see fig. B and remove the top cover, see fig. C.

5.Close the shut off valve on the inlet hose.

6.Open the drain valve by lifting up the release button (1) and pulling the valve out (2), see fig. D.

7.Open the filter housing lid by turning it as indicated on the lid, see fig. E.

8.When the water purifier is empty, close the valve by lift- ing up the release button and pushing in the valve (3), see fig. D.

Note! Ensure that the edge of the catch really locks the drain valve in the inner position.

B

C

D

1

2

3

E

8

Page 8
Image 8
Dometic CWP 5311 user manual Draining