CERTIFIED INSTALLATION

CERTIFIED INSTALLATION

Certified installations require one roof vent and one lower side vent.

For “Certified Vent System Kits” see page 16.

For further information contact your dealer or distributor.

NOTE: The upper vent should be centered over the condenser coil at the back of the refrigerator.

Minimum ventilation height

Condenser

FIG. 9

METHODS OF INSTALLATION

The method of installation is shown in FIG. 9.

It is essential that all maximum or minimum dimensions are strictly maintained, as the performance of the refrig- erator is dependent on adequate flow of air over the rear of the refrigerator.

VENTILATION HEIGHTS

Installation with roof

Minimum ventilation

vent and lower side vent

heights in:

 

 

 

 

Refrigerator

Inches

mm

NDR1062

 

 

63-3/4

1620

 

 

 

 

G

K

K

FIG. 10

L

 

NOTE: Wood Strip

METHODS OF INSTALLATION MUST be in place

N

M

CLEARANCES

Minimum clearances in inches to combustible materials

are:

 

 

G:

Top

0

K:

Side

0

L:Bottom 0

M:Rear 0

N:See NOTE: Clearance “N” below.

NOTE: Clearance “M” is between the rearmost part of the refrigerator and the wall behind the refrigerator.

NOTE: Clearance “N” is the distance between the bot- tom of the lower side vent to the roof material. For ven- tilation height, see table VENTILATION HEIGHTS.

See Figures 9 and 10.

7