Troubleshooting

Related Messages

When the unit's power is ON, messages such as those shown below may be displayed. When any such message is displayed on the screen, please respond as described below. If the same message is displayed after the treatment, or if a message other than the following appears, please contact your dealer or service company.

Message

Description

 

 

CHANGE THE LAMP

Lamp usage time is approaching 2000 hours. (*2)

AFTER REPLACING LAMP,

Preparation of a new lamp, and an early lamp change is

RESET THE LAMP TIMER.

recommended. After you have changed the lamp, please be

(*1)

sure to reset the lamp timer.

 

 

CHANGE THE LAMP

Lamp usage time is approaching 2000 hours. (*2)

AFTER REPLACING LAMP,

A lamp change within ** hours is recommended. When lamp

RESET THE LAMP TIMER.

usage reaches 2000 hours, the power will automatically be

THE POWER WILL TURN OFF

turned OFF. Please change the lamp by referring to the “Lamp”

AFTER ** hr.

section of this manual. After you have changed the lamp,

please be sure to reset the lamp timer.

(*1)

 

 

CHANGE THE LAMP

As lamp use has reached 2000 hours (*2), the power will soon

AFTER REPLACING LAMP,

be automatically turned OFF.

RESET THE LAMP TIMER.

Please immediately turn the power off, and change the lamp by

THE POWER WILL TURN OFF

referring to the “Lamp” section of this manual. After you have

AFTER 0 hr.

changed the lamp, please be sure to reset the lamp timer.

 

 

 

NO INPUT IS DETECTED

There is no input signal.

Please confirm the signal input connection, and the status of the

ON ***

signal source.

 

 

 

SYNC IS OUT OF RANGE

The horizontal or vertical wavelength of the inputted signal is

outside of the response parameters of this unit.

ON *** fH *****kHz fV *****Hz

Please confirm the specs for this unit or the signal source

 

specs.

 

 

 

The internal portion temperature is rising.

 

Please turn the power OFF, and allow the unit to cool down at

 

least 20 minutes. After having confirmed the following items,

CHECK THE AIR FLOW

please turn the power ON again.

 

Is there blockage of the air passage aperture?

 

Is the air filter dirty?

 

Does the peripheral temperature exceed 35°C?

NOTE (*1) • Although this message will be automatically disappeared after around 3 minutes, it will be reappeared

every time the power is turned ON.

(*2) • Lamps have a finite product life. Lamps are characterized by the fact that, after long hours of usage, a lamp will no longer light up, or the lamp will break or burst, etc. This unit is equipped with an automatic shut-down function, such that the power will automatically be turned OFF when lamp usage time has reached 2,000 hours. Please be aware, however, that among lamp types, there are major differences in product lifetimes; a lamp may thus fail to light even prior to the functioning of the automatic shut-down function of this unit.

38

Page 40
Image 40
Dukane 8055 user manual Troubleshooting, Related Messages

8055 specifications

The Dukane 8055 is an advanced ultrasonic welding machine designed to deliver exceptional performance for various manufacturing applications. Known for its precision and reliability, the Dukane 8055 is ideal for industries such as automotive, medical, and electronics, where high-quality joining processes are crucial.

One of the standout features of the Dukane 8055 is its robust ultrasonic technology. It employs high-frequency sound waves to create localized heating at the joint interface of thermoplastic materials. This method significantly reduces cycle times, improving productivity while ensuring consistent weld quality. The 8055 offers an adjustable frequency capability, allowing operators to optimize the welding process based on the specific materials being used.

The machine's user-friendly interface includes a touchscreen control panel, making it easy to set parameters and monitor the welding process in real time. This feature enhances operational efficiency by enabling quick adjustments to be made on the fly, ensuring that production runs smoothly.

Another significant characteristic of the Dukane 8055 is its integration with advanced software systems. The machine comes equipped with data logging capabilities, allowing users to track and analyze performance metrics. This data can be instrumental in identifying trends, ensuring compliance with industry standards, and implementing continuous improvement initiatives.

The Dukane 8055 also prioritizes safety and reliability. It is designed with various safety features, including automatic shutdown in case of abnormalities, ensuring minimal risk to operators and equipment. The robust construction of the machine ensures longevity even under demanding production environments.

Additionally, the Dukane 8055 is versatile, capable of accommodating various welding tools and accessories. This flexibility allows manufacturers to easily switch between different applications, from complex assembly tasks to simple joining processes, making it a valuable asset to any production line.

In summary, the Dukane 8055 ultrasonic welding machine stands out with its advanced technology, user-friendly controls, data logging features, and robust design. Its ability to adapt to various applications while ensuring high-quality results makes it an exemplary choice for manufacturers seeking efficiency and reliability in their joining processes. With the Dukane 8055, companies can enhance their production capabilities while maintaining the highest standards of quality.