Regarding The Indicator Lamps

Troubleshooting (continued)

Regarding The Indicator Lamps

ATTENTION • When the interior portion has become overheated, for safety purposes, the power source is automatically turned off, and the indicator lamps may also be turned off. In such a case, press the “” (power OFF) side of the main power switch, and wait at least 45 minutes. After the unit has sufficiently cooled down, please make confirmation of the attachment state of the lamp and lamp cover, and then turn the power on again.

Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have the meanings as described in the table below. Please respond in accordance with the instructions within the table. If the same indication is displayed after the treatment, or if an indication other than the following is displayed, please contact your dealer or service company.

POWER

LAMP

TEMP

Description

indicator

indicator

indicator

 

 

 

 

 

Lighting in

Turned off

Turned off

The unit is in a standby state. Please refer to the “Power

orange

ON/OFF” section of this manual.

 

 

 

 

 

 

Flashing in

Turned off

Turned off

The unit is warming up. Please wait.

green

 

 

 

Lighting in

Turned off

Turned off

The unit is in an ON state. Ordinary operations may be

green

performed.

 

 

 

 

Flashing in

Turned off

Turned off

The unit is cooling down. Please wait.

orange

 

 

 

 

 

 

The unit is cooling down. A certain error has been detected.

Blinking in

-

-

Wait until the POWER indicator has finished flashing, and then

red

perform the proper response measure using the item

 

 

 

 

 

descriptions below as reference.

 

 

 

 

 

 

 

The projector lamp has not been properly fixed (attached),

 

 

 

the projector lamp does not light, and/or there is a possibility

 

 

 

that the interior portion has become heated. Turn the power

Lighting or

 

 

OFF and wait at least 20 minutes. After the unit has sufficiently

Lighting in

Turned off

cooled down, please make confirmation of the following items,

blinking in

and then turn the power ON again. If the same indication is

red

red

 

displayed, please change the lamp.

 

 

 

 

 

• Is there blockage of the air passage aperture?

 

 

 

• Is the air filter is dirty?

 

 

 

• Does the peripheral temperature exceed 35°C?

 

 

 

 

Lighting or

 

 

The lamp cover has not been properly fixed (attached). Turn

Blinking in

 

the power OFF and wait at least 45 minutes. After the unit has

blinking in

Turned off

sufficiently cooled down, please make confirmation of the

red