STORING / MAINTAINING YOUR SPRAYER
•The sprayer should be stored out of direct sunlight in a cool dry space.
•Before freezing weather make sure to drain all liquid in the tank, pump, pressure cylinder, hose,
(See “Cleaning” section). Lock the
•When service is required call your nearest dealer and always insist on original manufactured replacement parts.
•Inspect the hose, wand, pump, tank and
TROUBLE SHOOTING YOUR SPRAYER |
| |
Symptom | Possible Reason | Correction |
|
|
|
Difficulty actuating the pump handle and/or | Upper valve plate sticks | Clean or replace valve plate |
pump handle moves itself back up. | Piston cylinder outlet passage clogged | Clean piston cylinder outlet passage |
Little or no resistance during repeated pumping – no pressure.
Damaged/worn/dirty/upper valve plate | Clean or Replace Valve Plate |
Damaged /worn upper | Replace |
Piston Collar or piston cylinder | Replace Collar or Piston cylinder assembly |
assembly is worn |
|
Too much resistance after just a few | Not enough air cushion in the pressure | Release pressure in pressure chamber |
| ||
pumping strokes but pressure only lasts | chamber | Remove the hose & drain pressure |
| ||
briefly. |
|
| chamber. Reconnect the hose. |
| |
|
| Upper valve plate damaged/worn/dirty | Clean or replace upper valve plate |
| |
|
|
|
|
|
|
Upward pumping action is more difficult | Vent hole is clogged | Clear the vent hole in cap |
| ||
and/orpump handle moves itself backdown. | Lower valve plate sticks | Clean or replace the valve plate |
| ||
|
| Clogged intake filter | Clean the |
| |
|
|
|
| cartridge filter |
|
|
| Piston cylinder intake clogged | Clean piston cylinder intake |
| |
|
|
|
|
|
|
Leaks at Piston Cylinder | Damaged/worn/Dirty Collar | Clean or Replace Piston Collar |
| ||
|
|
|
|
|
|
|
| Damaged Piston Cylinder | Replace Piston Cylinder |
| |
|
|
|
|
|
|
|
| Damaged Piston | Replace Piston |
| |
|
|
|
|
| |
Connections loose | Tighten connection |
| |||
|
|
|
|
|
|
|
| Worn or damaged | Rebuild or replace the |
| |
|
|
|
|
|
|
Wand assembly leaks | Connections loose | Tighten connection |
| ||
|
|
|
|
|
|
|
| Damaged or worn | Replace |
| |
|
|
|
|
|
|
Nozzle assembly leaks | Connections loose | Tighten connection |
| ||
|
|
|
|
|
|
|
| Damaged or worn | Replace |
| |
|
|
|
|
| |
Leak between pump assembly | Pump clamp loose | Tighten clamp |
| ||
|
|
|
|
| |
and tank | Replace pressure chamber oring |
| |||
|
|
|
|
| |
Hose leaking at tank outlet | Hose clamp loose | Tighten clamp |
| ||
|
|
|
|
| |
Hose leaking at | Connection loose | Tighten retaining nut |
| ||
|
|
|
|
|
|
|
| Damaged or worn | Replace |
|
6E