2.3 Power Supply Troubleshooting

2 Troubleshooting Procedures

Procedure 2 Error Code Check

If the power supply microprocessor detects a malfunction, it indicates the error code as shown below.

The error code begins with the least significant digit.

Error code

Error code

Where Error occurs

 

 

 

 

 

1*h

Adaptor

AC Adaptor is not connected.

 

(AC Adaptor, DS)

Error code begins with : 0x10

 

 

Error code ends with

: 0x1F

 

 

 

2*h

The 1st battery

The 1st Battery is not connected.

 

 

Error code begins with : 0x20

 

 

Error code ends with

: 0x2F

 

 

 

3*h

The 2nd Battery

The 2nd Battery is not connected.

 

 

Error code begins with : 0x30

 

 

Error code ends with

: 0x3F

 

 

 

 

4*h

S3V output

Operating Power ON

 

 

 

 

5*h

1R5-C1V output

Error code begins with : 0x40

 

 

 

6*h

1R8-C1V output

Error code ends with : 0xDF

 

 

 

 

7*h

PPV output

 

 

 

 

 

 

8*h

PGV output

 

 

 

 

 

 

9*h

E5V output

 

 

 

 

 

 

A*h

E3V output

 

 

 

 

 

 

B*h

1R2-P1V output

 

 

 

 

 

 

C*h

PTV output

 

 

 

 

 

 

D*h

1R25-P1V output

 

 

 

 

 

 

E*h

2R5-E2V output

 

 

 

 

 

 

F*h

 

 

 

 

 

 

 

TECRA M1 Maintenance Manual (960-436)

2-7

Page 63
Image 63
Toshiba tecra m1 manual Power Supply Troubleshooting Troubleshooting Procedures, Procedure 2 Error Code Check