2 Troubleshooting Procedures | 2.3 Power Supply Troubleshooting |
| ||
PGV output |
|
|
| |
|
|
|
|
|
| Error code |
| Meaning |
|
|
|
|
| |
| 80h | PGV voltage is over 1.92V when the computer is powered on/off. |
| |
|
|
|
| |
| 81h | PGV voltage is 0.68V or less when the computer is powered on. |
| |
|
|
|
| |
| 82h | PGV voltage is 0.68V or less when the computer is booting up. |
| |
|
|
|
| |
| 83h | PGV voltage is 0.68V or more when the computer is powered off. |
| |
|
|
|
| |
| 84h | PGV voltage is 0.68V or less when the computer is suspended. |
| |
|
|
|
|
|
E5V output |
|
|
| |
|
|
|
|
|
| Error code |
| Meaning |
|
|
|
|
| |
| 90h | E5V voltage is over 6.00V when the computer is powered on/off. |
| |
|
|
|
| |
| 91h | E5V voltage is 4.50V or less when the computer is powered on. |
| |
|
|
|
| |
| 92h | E5V voltage is 4.50V or less when the computer is booting up. |
| |
|
|
|
|
|
| 93h | E5V voltage is 4.50V or more | when the computer is powered off. |
|
|
|
|
| |
| 94h | E5V voltage is 4.50V or less when the computer is suspended. |
| |
|
|
|
|
|
E3V output |
|
|
| |
|
|
|
|
|
| Error code |
| Meaning |
|
|
|
|
| |
| A0h | E3V voltage is more than 3.96V when the computer is powered on/off. |
| |
|
|
|
| |
| A1h | E3V voltage is 2.81V or less when the computer is powered on. |
| |
|
|
|
| |
| A2h | E3V voltage is 2.81V or less when the computer is booting up. |
| |
|
|
|
| |
| A3h | E3V voltage is 2.81V or more when the computer is powered off. |
| |
|
|
|
| |
| A4h | E3V voltage is 2.81V or less when the computer is suspended. |
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Error code |
| Meaning |
|
|
|
|
| |
| B0h |
| ||
|
|
|
| |
| B1h |
| ||
|
|
|
| |
| B2h |
| ||
|
|
|
| |
| B3h |
| ||
|
|
|
|
|
TECRA M1 Maintenance Manual |