3.6 Keyboard Test 3 Tests and Diagnostics
Subtest 03 PS/2 Mouse Connect Check
NOTE: To execute the PS/2 mouse connect check, a PS/2 mouse must be
connected to the computer before the power is turned on.
This subtest checks whether a PS/2 mouse is connected or not.
If this test does not detect an error, it returns to the subtest menu.
If this test detects an error, the following message appears.
DATA COMPARE ERROR
[[ HALT OPERATION ]]
1: Test end
2: Continue
3: Retry
Subtest 04 Touch Pad/IPS
This subtest checks the functions of the pointing stick as shown below.
A) Touch Pad/IPS stick pressure sensing direction and parameter.
B) Touch Pad/IPS switch function check.
This test reports the pointing stick motion response from the IPS and IPS
switch. When the stick is pressed towards the upper left, the <DIRECTION>
display changes according to the following illustration. If an IPS switch is
pressed, the <LAT> displays appear on the right side one by one. The
parameters appear on the center of the display. To exit this subtest, press the
four IPS switches at the same time.