2 Troubleshooting Procedures | 2.3 Power Supply Troubleshooting |
| ||
Check 1 Compare the patterns in the hexadecimal error code to the tables below. |
| |||
DC IN |
|
|
| |
|
|
|
|
|
| Error code |
| Meaning |
|
|
|
|
| |
| 10h | AC Adaptor output voltage is over 16.5V. |
| |
|
|
|
| |
| 11h | Common Dock voltage is over 16.5V. |
| |
|
|
|
| |
| 12h | Current from the DC power supply is over 6.05A. |
| |
|
|
|
| |
| 13h | Current from the DC power supply is over 0.5A when there is no load. |
| |
|
|
|
| |
| 14h | Current sensing IC is not normal. |
| |
|
|
|
|
|
1st Battery |
|
|
| |
|
|
|
|
|
| Error code |
| Meaning |
|
|
|
|
| |
| 20h | Main battery charge current is more than 6.05 A. |
| |
|
|
|
| |
| 21h | Main battery charge current is over 6.05A. |
| |
|
|
|
| |
| 22h | Main battery discharge current over 0.5A. |
| |
|
|
|
| |
| 23h | Main battery charge current is over 4.3A. |
| |
|
|
|
| |
| 24h | Current sensing IC is not normal. |
| |
|
|
|
| |
| 25h | Main battery charge current is over 0.3A. |
| |
|
|
|
|
|
2nd Battery |
|
|
| |
|
|
|
|
|
| Error code |
| Meaning |
|
|
|
|
| |
| 30h | Overvoltage is detected. (Not supported) |
| |
|
|
|
| |
| 31h | Main battery charge current is over 6.05A. |
| |
|
|
|
| |
| 32h | Main battery discharge current is over 0.5A. |
| |
|
|
|
|
|
| 33h | Main | battery charge current is over 3.1A. |
|
|
|
|
| |
| 34h | Current sensing IC is not normal. |
| |
|
|
|
| |
| 35h | Secondary battery charge current is over 0.3A. |
| |
|
|
|
|
|
TECRA M1 Maintenance Manual |