Edelweiss EQ1-DYN Controls, Adjusting Band Parameters, Peaking-Filter, Dynamic-Peaking, CH1 & CH2

Models: EQ1-DYN

1 27
Download 27 pages 13.74 Kb
Page 9
Image 9
Adjusting Band Parameters

OPERATING INSTRUCTIONS FOR GAMBIT EQUALIZER EQ1-DYNOPERATION

Adjusting Band Parameters

 

 

Controls

To adjust boost, Q/ slope or frequency

simply

See Graph 1: Front Panel Elements, Ž.

turn the corresponding knob (see Table 1).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

“boost”

 

“Q/ slope”

“frequency”

 

 

Peaking-Filter

set boost

 

set Q

 

set centre frequency

 

 

Dynamic-Peaking

set boost

 

set Q / threshold

set centre frequency

 

 

Shelve-Filter

set boost

 

set shape

 

set 3dB frequency

 

 

Cut-Filter

-

 

set slope

 

set -3dB frequency

 

Table 1

To adjust the mode, activate the band. Press a key (Table 2) to change the mode value. The ac- tive mode is highlighted and the adjacent softkey is lit.

CH1 & CH2

These two keys patch the band controls to the according channels. The band controls can either be separate for each channel or ganged together.

 

Key A

 

Mode

toggle lo- / hi-

 

 

shelve

 

Key B

toggle peaking /dynamic peaking

Key C

toggle lo- / hi-cut

Key D

bypass

Table 2

If the band bypass is on (highlighted), its filter settings (type and parameters) are saved but have no effect on the audio signal. Turning bypass off will restore the previous band settings.

Bypassing all bands is sonically equivalent to using the overall bypass (refer to EQ Bypass) if the gain is set to 0.0dB.

The key is lit for the active channel.

To copy CH1 settings to CH2 or vice versa, press the “copy” key and select an option (Graph 6).

Ganged

When this key is lit, the band controls act for both channels simultaneously. Switching channels while the “ganged” key is lit will activate CH1 and CH2 settings alternately for both channels.

Only bands 1, 2, 5, and 6 can be set into dynamic mode. This allows for linear gain adjustment be- fore and after a dynamic band.

If ganged is off, the controls will affect the active channel only.

Daniel Weiss Engineering Ltd., Florastr. 42, CH-8610 Uster

 

Page 9 of 27

) +41 1 940 20 06 2 +41 1 940 22 14

8 http://www.weiss.ch

* weiss@weiss.ch

Page 9
Image 9
Edelweiss EQ1-DYN Controls, Adjusting Band Parameters, Peaking-Filter, Dynamic-Peaking, Shelve-Filter, Cut-Filter, Mode