Design Spot 300 Pro™
©Elation Professional, Los Angeles Ca. 27 www.ElationLighting.com
8.3.4 Lamp Off Via DMX
When engaged, this function will allow the lamp to be switched “off” via a DMX controller.
Select “ON” to enable this function or “OFF” to disable it.
8.3.5 Lamp Off No DMX
When engaged, this function will automatically switch the lamp “off” when the fixture
loses a DMX signal. The function can be set with a delay time of 1 ~ 19 minutes. To
disable this function select “OFF” in the system menu. To enable this function select
“XX M” Where XX represents the hold time before lamp shut down.
8.3.6 Lamp On at Temp.
The fixture is designed to shut the lamp off when an excessive temperature is sensed
inside the head by the on-board CPU. The lamp is shut down to prevent damage to the
lamp and avoids possible internal damage to the head. This function sets the minimum
temperature for lamp restrike after the lamp has been automatically shut off.
8.3.7 Lamp Off at Temp.
The fixture is designed to shut the lamp off when an excessive temperature is sensed
inside the head by the on-board CPU. The lamp is shut down to prevent damage to the
lamp and avoids possible internal damage to the head. This function sets the maximum
internal operating temperature of the head before the lamp will automatically be shut
down. This function can be set to activate at an internal temperature between 80° C and
139° C. Inside temperatures below 90° C are not critical. Temperatures above 90° C
should lead to the lamp being switched off. Please note that the outside temperature
should not exceed 45° C.
8.4 Personality:
8.4.1 Status setting
Address via DMX - This function allows the DMX address to remotely be adjusted
from a DMX console. This setting requires special settings for both the controller and