Design Spot 300 Pro™
©Elation Professional, Los Angeles Ca. 51 www.ElationLighting.com
Rotating gobo indexing error:
The gobo is not located in the default position after start-up or after a reset command. This
message will appear after a fixture reset if the gobo positioning magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
Fix Gobo-wheel error:
This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive
circuit on the main PCB). The fix gobo wheel is not located in the default position after the
reset.
Prism-wheel error:
This message will appear after the reset of the fixture and if the magnetic -indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driver circuit on the main PCB). The Prism wheel is not located in the default position after
the reset.
Focus-error:
This message will appear after the reset of the fixture and if the magnetic indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driver circuit on the main PCB). The focus motor is not located in the default position after
the reset.
Shutter, Strobe error:
(Shutter, Strobe-wheel error) This message will appear after the reset of the fixture if the
yoke’s magnetic-indexing circuit malfunction (sensor failed or magnet missing) or the
stepping-motor is defective (or its driving IC on the main PCB). The Shutter, Strobe -wheel is
not located in the default position after the reset.
Iris-error:
This message will appear after the reset of the fixture and if the magnetic indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its