Design Spot 300 Pro™
©Elation Professional, Los Angeles Ca. 30 www.ElationLighting.com
Low will send normal voltage to the fan, for normal operation. High will send slightly
higher voltage to fans that allows the fans to operate at higher than normal speeds.
This setting should only be used in extreme cases of higher than normal
temperatures. Using the fans in “HIGH” mode will decrease fan life over time. Low is
the default setting.
Gobo Speed: This function will change the speed at which the gobo wheel moves.
This function allows Design Spot 300 Pros and Design Spot 250s to be implemented
together in the same rig. There are two different settings, “Quick” and “Slow.” Slow
will move the gobo wheel at a speed that matches the first generation Design Spot
250. The “Quick” setting will advance the wheel at a new, faster rate than the original
Design Spot 250. “Quick” is the default setting.
8.4.3 Fans Control - This function is used to change the functionality of the internal
cooling fans. The available selections are: 1) “AUTO” – The fans will automatically
switch between low and high speeds depending on the internal operating temperature. 2)
“HIGH” – The fans will run in high-speed mode regardless of operating temperature. 3)
“LOW” – The fans will remain in low speeds regardless of internal operating
temperature.
8.4.4 Display Settings – The display is designed to turn off during normal operation to
avoid excessive light in situations that require an extremely dark environment. This
function will adjust the time delay the fixture will before it turns off. This function is
disabled as default.
8.4.5 Temperature C/F – This function changes the temperature the unit will display
from either Celsius or Fahrenheit. Celsius is set as default.
8.4.6 Initial effect – This function allows a user to create and assign a custom “Home
Position” into the fixture. Adjusting the Pan and Tilt values then locking those values into