4Installation Requirements
Electrical system requirements
NOTE
Because of potentially inconsistent voltage capabilities, the use of this dryer with power created by gas powered generators, solar powered generators, wind powered generators or any other generator other than the local utility company is not recommended.
ELECTRICAL REQUIREMENTS FOR ELECTRIC DRYER:
CIRCUIT - Individual 30 amp. branch circuit fused with 30 amp. time delay fuses or circuit breakers. Use separately fused circuits for washer and dryer. DO NOT operate a washer and a dryer on the same circuit.
POWER SUPPLY -
IMPORTANT
This dryer is internally grounded to neutral unless it was manufactured for sale in Canada.
Only a
(1)new branch circuit installations, (2) mobile homes,
(3)recreational vehicles, and (4) areas where local codes do not permit grounding through the neutral.
3-wire receptacle
(NEMA type 10-30R)
The dryer MUST employ a
4-wire receptacle
(NEMA type 14-30R)
The dryer MUST employ a
NOTE
Dryers manufactured for sale in Canada have
OUTLET RECEPTACLE - NEMA
GROUNDING CONNECTION - See “Grounding requirements” in Electrical Installation section.
ELECTRICAL REQUIREMENTS FOR GAS DRYER:
CIRCUIT - Individual, properly polarized and grounded 15 amp. branch circuit fused with 15 amp. time delay fuse or circuit breaker.
POWER SUPPLY -
POWER SUPPLY CORD - The dryer is equipped with a 120 volt
GROUNDING CONNECTION - See “Grounding requirements” in Electrical Installation section.
Grounding type wall receptacle
Do not, under
any circumstances, cut, remove,
or bypass the grounding prong.
Power cord with