Electrolux EDB 872 manual Technical Details, Rear top right hand side of appliance Rc½ ½ B.S.P

Models: EDB 872

1 44
Download 44 pages 37.55 Kb
Page 34
Image 34
TECHNICAL DETAILS

TECHNICAL DETAILS

Loading Info:

 

 

 

 

Grill Burner

Natural Gas

L.P. Gas

 

 

Heat Input

2.8kW (9554 Btu/h)

2.8kW 201 g/h

 

Injector Marking

123

089

 

 

Main Oven

 

 

 

 

Heat Input

1.7kW (5800 Btu/h)

1.7kW 122 g/h

 

Injector Marking

095

 

 

 

Flame Supervision Device

Diamond 'H' GSD 100/28

Diamond

'H'

GSD

 

 

100/30

 

 

Thermostat

Diamond 'H' 1100 - 122/B2

Diamond

'H'

1100 -

 

 

123/B2

 

 

Thermostat By-Pass Marking

74

79

 

 

Oven Light:

0.05kW

 

 

 

Control Cooling Fan

0.020kW

 

 

 

Timer:

0.005kW

 

 

 

Height:

Appliance 760 mm

Installed 720 mm

Width:

593 mm

 

 

 

Depth:

550 mm

 

 

 

(excluding handles and knobs)

 

 

 

 

Weight:

49kg

 

 

 

Connection:

Rear top right hand side of appliance Rc½ (½" B.S.P.

 

Gas

Female￿

 

 

 

Electric

230/240 Volt A.C. 50Hz Mains 3 core cable and moulded

 

plug fused to 3 amps.

 

 

 

IMPORTANT - SAFETY REQUIREMENTS

This appliance must be installed in accordance with the Gas Safety (Installation and Use) Regulations Current Editions. Detailed recommendations are contained in the following British Standard Codes of Practice - BS.6172, BS.5440: Part 2 and BS.6891. All British Standards must be 'Current Editions'.

PROVISION FOR VENTILATION

This appliance is not connected to a combustion products evacuation device. It shall be installed and connected in accordance with the current installation regulations. Particular attention shall be given to the relevant requirements regarding ventilation.

The room containing the appliance should have an air supply in accordance with BS. 5440: Part 2 Current Edition. All rooms require an openable window or equivalent and some rooms will require a permanent vent as well. For room volumes up to 5m³ an air vent of 100cm² is required: for room volumes between 5m³ and 10m³ an air vent of 50cm² is required. If the room has a door that opens directly to the outside, no air vent is required. For room volumes that exceed 11m³ no air vent is required. If there are other fuel burning appliances in the same room, BS.5440: Part 2 Current Edition should be consulted to determine the requisite air vent requirements.

Prolonged intensive use of the appliance may call for additional ventilation, for example opening a window, or more effective ventilation, for example increasing the level of mechanical ventilation where present.