TECHNICAL DATA
DIMENSIONS |
| Height | Width | Depth | |
Overall |
|
| 595 | 595 | 595 |
Flexible Gas Pipe |
|
|
|
| |
Minimum Cabinet |
| 575 | 560 | 575 | |
Solid Gas Pipe |
|
|
|
|
|
Minimum Cabinet |
| 575 | 560 | 560 | |
Maximum Cabinet |
| 600 | 570 | N/A | |
Weight of Appliance |
| 34kg |
|
| |
Minimum Clearance top of |
|
|
|
| |
Appliance to Roof of Cabinet |
| 3mm (1/8") |
|
| |
CONNECTIONS |
|
|
|
| |
Gas | Flexible Hose |
| Rear top right hand side of appliance |
| |
|
|
| Rc½ (½" B.S.P. Female). |
| |
| Solid Pipe |
| Right hand side of appliance above grill |
| |
|
|
| Behind control panel Rc¼ (¼" B.S.P. Female) | ||
Electrical |
|
| Rear of appliance at bottom left hand side | 240V a.c. 50Hz | |
GENERAL |
|
|
|
|
|
Timer |
|
| Eaton EL191 |
|
|
Pressure test point |
| Top right hand corner behind fascia. |
| ||
Solenoid valve |
|
| Teddington SOVRBB01G |
| |
IGNITION |
|
|
|
|
|
Spark Generator |
| Flame Suppressed H.T. spark 240V APCO D9805 | |||
Spark Gap |
|
|
|
| |
GRILL |
|
| Natural Gas |
| L.P.Gas |
Burner | Steel tubular burner with expanded metal frets. |
| |||
Heat Input | 2.8kW (9556 Btu/h) |
|
| 2.8kW (201 g/h) | |
Injector Marking | 123 |
|
|
| 089 |
OVEN |
|
| Natural Gas |
| L.P.Gas |
Burner | Sheet metal construction mounted transversely at rear of oven. | ||||
Heat Input |
|
| 2.4kW (8189 btu/h) |
| 2.4kW (172 g/h) |
Injector Marking |
|
| 108 |
| 078 |
Flame Supervision Device |
| Diamond 'H' G.S.D. 100/28 | Diamond 'H' G.S.D100/30 | ||
Thermostat |
|
| Diamond 'H' 1100/141/B2 | Diamond 'H'1100/142/B2 | |
Thermostat | 74 |
| 79 |
37