LOCATION OF APPLIANCE

The appliance may be located in a kitchen, a kitchen/diner or bedsitting room, but not located in a bathroom , shower room, or garage.

It is essential that there is a minimum clearance of 3mm between the top surface of the appliance and

the inside top of the cabinet. The unit must be fitted into a cabinet conforming to Fig. 1. The following internal dimensions are particularly important.

 

Height

575

Minimum 600

Maximum

 

Width

560

Minimum 570

Maximum

Solid Pipe

Depth

560

Minimum

N/A

Maximum

Flexible Pipe

Depth

575

Minimum

N/A

Maximum

NOTE: Where a cupboard door with a handle is situated above the appliance, we recommend a minimum clearance gap of 5mm between fascia top trim and door. If the appliance is to be installed next to a cupboards' doors or draws, we recommend that the cabinet heat deflectors, supplied with the appliance be fitted. These are located behind the front frame and secured in position by the fixing screws (see Installation Section). This oven unit may be used in a Built-in or a Built-under situation. If the appliance is to be Built-under

a hob, it is recommended that the hob be installed before the oven unit.

L.P.G. cookers MUST NOT be installed below ground level, i.e. in a basement, or aboard any boat, yacht or other vessel.

595

570

600

5

575 min600 max

600

min

 

560min 570 max

2000 recommended

540

min 560

FIG.1