importantoperating safetyconditions/energyinstructions tips/inclusionselectrolux EXP09CS1WIelectrolux EXP09CS1WI

Points to keep in mind when using your air conditioner

Warnings for use

Do not modify any part of this product.

Do not insert anything into any part of the unit.

Ensure the power supply used has an appropriate voltage rating. Only use a 220V – 240V, 50Hz,10A mains electricity supply. Use of a power supply with an improper voltage rating can result in damage to the unit and possibly fire.

Always use a circuit breaker or fuse with the proper amp rating.

Do not, under any circumstances, use wire, pins or other objects in place of a proper fuse.

In the event of any abnormality with the air conditioner (eg. a burning smell), turn it off immediately and disconnect the power supply.

Warning for power supply cord

This power plug must only be plugged into an appropriate wall socket. Do not use in conjunction with any extension cords.

Push the power plug securely into the socket and make sure it is not loose.

Do not pull, deform, or modify the power supply cord, or immerse it in water. Pulling or misuse of the power supply cord can result in damage to the unit and cause electrical shock.

If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard. Use only the manufacturer specified power cord for replacement.

This appliance must be earthed. This appliance is equipped with a cord having an earth wire. The plug must be plugged into an outlet that is properly installed and earthed.

(only for UK)

This appliance is equipped with a cord that has a earthed wire connected to an earthed pin. The plug must be plugged into a socket that is properly installed and earthed. Do not under any circumstances cut or remove the square earthed pin from this plug.

square earthed pin

Usage cautions

Ventilate the room periodically during use, especially if using gas appliances in conjunction with the air conditioner.

Be sure to turn the unit off and disconnect the power supply cord before performing any maintenance

or cleaning.

Do not splash or pour water directly onto the unit. Water can cause electrical shock or equipment damage.

Drainage should be performed whenever moving the air conditioner (see page 19). If any water remains in the tank, it may spill out while being moved.

To ensure proper drainage, the drainage hose must have no kinks and must not be elevated during dehumidification mode. If not, the drained water may spill out into the room.

The temperature around the drainage hose must not be below freezing point when used. Drained water may freeze inside the hose, causing water inside the unit to overflow into the room.

Do not block the exhaust air outlet with obstacles. Cooling performance may be reduced or stop completely.

Provide a residual current device (RCD) in order to protect against electric shock in accordance with British Standard and Wiring Rules.

Exposure to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time.

Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Usage in such a manner could harm such property.

Notes on operation

Allow 3 minutes for the compressor to restart cooling.

If you turn the air conditioner off and immediately restart it, allow three minutes for the compressor to restart cooling. There is an electronic device in the unit that keeps the compressor turned off for three minutes

for safety.

In the event of a power failure during use, allow 3 minutes before restarting the unit. After power is reinstated, restart the air conditioner. If the power was off for less than three minutes, be sure to wait at least three minutes before restarting the unit. If you restart the air conditioner within three minutes, a protective device in the unit may cause the compressor to shut off. This protective device will prevent cooling for about 5 minutes. Any previous settings will be cancelled and the unit will return to its initial settings.

Low temperature operation: Is your unit freezing up? Freezing may occur when the unit is set close to 18°C in low ambient temperature conditions, especially at night. In these conditions, a further temperature drop may cause the unit to freeze. Setting the unit to a higher temperature will prevent it from freezing.

Dehumidification mode increases room temperature. The unit generates heat during dehumidification mode and the room temperature will rise. Warm air will be blown out from the Exhaust air outlet, but this is normal and does not indicate a problem with the unit.

This air conditioner blows the warm air generated by the unit outside the room via the exhaust hose while in cool mode. Accordingly, the same amount of air as that blown out will enter the room from outside through any openings into the room.

Page 7
Image 7
Electrolux LU4 9QQ user manual Points to keep in mind when using your air conditioner, Usage cautions