7 Commissioning
7.1 1-Phase Power Supply
This machine must be connected to an earthed outlet and operated on a residual current device (RCD) of 30 mA capacity. Supply voltage required 230V ±5% 50 Hz. Protect circuit with a fuse 16 A
7.2 3-Phase Power Supply
A
±5% 50 Hz. Protect circuit with 3 fuses 16 A
7.3 Direction Of Rotation
For machines with
Note:
With a wrong direction of rotation there is danger of accident. Check direction of rotation carefully. Have phases interchanged only by a qualified electrician!
7.4 Switch
This spindle moulder is started by actuating the green
7.5 Overload Protection
In case of an overload the
7.6 No-Voltage Release
The switch is equipped with a
7.7 Dust Collection
This spindle moulder must be connected to a dust collector. - The fine dust of beech or oak is classified as
The dust collector this spindle moulder is to be connected to must provide for a minimum air flow rate of 16 m/sec at the machine's dust extraction outlet.
The dust extraction outlet's nominal diameter is 100 mm.
7.8 Dust Collector Automatic Start
The electrical installation must provide for automatic starting of the dust collector when the spindle moulder is switched on, and for a 20 second