Elmo ExtrIQ Dragonfly/Butterfly, DRA- X/YY manual Connector J1, Short, Function, Description, Form

Models: ExtrIQ Dragonfly/Butterfly BUT- X/YYY DRA- X/YY

1 31
Download 31 pages 61.99 Kb
Page 17
Image 17
3.6.2Connector J1

Dragonfly/ Butterfly Installation Guide

Installation

MAN-DRBUIG (Ver. 1.1)

 

 

 

3.6.2Connector J1

3-7

Pin

Short

Function

 

Description

#

Form

 

 

 

 

 

 

1

EN+

Enable +

 

Positive voltage input of the “Amplifier Enable” function.

 

 

 

 

To enable operation of the amplifier, the optocoupler

 

 

 

 

must be energized by applying voltage between this pin

 

 

 

 

(+) and pin J1/22 (-).

 

 

 

 

The optocoupler is isolated from the amplifier. See Figure

 

 

 

 

3-4.

 

 

 

 

“OFF” voltage: 0 V < Vin < 1 V.

 

 

 

 

“ON” voltage: 2.5 V < Vin < 10 V, 5 V typically with

 

 

 

 

current consumption 2.5 mA.

2

AOK

Amplifier OK

When the amplifier under normal operating conditions,

 

 

 

 

this output is in the “active low“ state. When a failure

 

 

 

 

occurs, this output is changed to the “open” state.

 

 

 

 

The optocoupler is an isolated, open collector NPN type.

 

 

 

 

See Figure 3-4.

 

 

 

 

Maximum voltage = 30 V

 

 

 

 

Maximum current = 8 mA

 

 

 

 

“On” voltage: V OUT(On) < 0.8 V

 

 

 

 

Refer to Section 4.3.

 

 

 

 

3

SO1

Status output 1

Specifications same as in pin J1/2.

4

HA

Hall A input

Logic levels: TTL

 

 

 

 

Maximum input voltage: 15 VDC.

5

HB

Hall B input

Logic levels: TTL

 

 

 

 

Maximum input voltage: 15 VDC.

6

HC

Hall C input

Logic levels: TTL.

 

 

 

 

Maximum input voltage: 15 VDC.

7

LATCH

Latch mode

Latch mode input. For more details see the Latch Mode

 

 

 

 

section in Chapter 4.

 

 

 

 

 

8

ECLRET

Current

limits

Current limit signals return.

 

 

return

 

 

9

ECLC

External

limit

External voltage scales down the rated value.

 

 

current

Voltage range: 0 V to 3.75 V (3.75 V = rated Ic)

 

 

continuous

 

 

Refer to Section 4.2.

 

 

 

 

10

CM

Current

 

Analog output with a scale of ± 3.9 V for ± Ip.

 

 

monitor

 

Output resistance: 1 kΩ

 

 

 

 

11

CREF+

Current

 

Positive input of a differential amplifier:

 

 

command

Input operating voltage range: ±3.75 V

 

 

positive

 

 

 

 

Maximum input voltage: ±20 V

 

 

 

 

 

 

 

 

Maximum common mode voltage: ±6 V

 

 

 

 

Differential input impedance: 40 kΩ

 

 

 

 

Refer to Section 4.1.

 

 

 

 

 

12

CREF-

Current

 

Negative input of a differential amplifier.

 

 

command

Same specification as in pin J1/11.

 

 

negative

 

 

 

 

 

13

CMRET

Current

 

Current monitor (CM) signal return.

 

 

monitor return

 

Page 17
Image 17
Elmo ExtrIQ Dragonfly/Butterfly, DRA- X/YY, BUT- X/YYY manual Connector J1, Short, Function, Description, Form