Raven Installation Guide

Servo Control Operation

MAN-RAVIG (Ver. 1.1)

 

 

 

4-5

4.8Status Indications

The following table lists the Raven amplifier status indications.

 

 

Latch

 

 

 

 

 

Function

Option

AOK

SO1

SO2

SO3

1

Amplifier OK

N/A

Low

Open collector

Open collector

Open collector

 

(AOK)

 

 

 

 

 

2

External disable

No

Low

Low

Open collector

Low

3

Current limit

No

Low

Open collector

Open collector

Low

4

Short

Yes

Open collector

Low

Open collector

Low

5

Over

Yes

Open collector

Open collector

Low

Low

 

temperature

 

 

 

 

 

6

Internal supplies

No

Open collector

Low

Low

Open collector

 

protection

 

 

 

 

 

7

Under voltage

No

Open collector

Low

Open collector

Open collector

8

Over voltage

No

Open collector

Open collector

Low

Open collector

9

Shunt*

No

Low

Open collector

Low

Open collector

10

Power Up Reset

No

Open collector

Open collector

Open collector

Open collector

*This indication can be used as a digital input for activating an external shunt regulator.

Table 4-3:Raven Status Indications

Notes:

Without latch mode:

The status indications are reset when the fault disappears.

With latch mode:

The Short and Over Temperature Failure status indications are reset when the enable signal is temporarily removed from the enable input.

Multiple faults:

Only the reading of the first fault is reliable. Additional faults add on to the status outputs and the indication is therefore meaningless.

Page 24