Raven Installation Guide

Installation

MAN-RAVIG (Ver. 1.1)

 

 

 

3-8

Pin #/

 

 

Short Form

Function

Remarks

1

Amplifier OK

“Amplifier OK” indication output pin. When the

AOK

 

amplifier is at normal operating conditions, this

 

 

output is in “active low “ state. When a failure

 

 

occurs, this output is changed to “open” state.

 

 

Opto isolated, open collector NPN type. See

 

 

Figure 2-1.

 

 

Maximum voltage = 30 V

 

 

Maximum current = 8 mA.

 

 

“On” voltage: V OUT(On) < 0.8 V

2

Status output 1

Status indication output 1. Specification as in pin

SO1

 

J3/1.

3

Status output 2

Status indication output 2. Specification as in pin

SO2

 

J3/1.

4

Status output 3

Status indication output 3. Specification as in pin

SO3

 

J3/1.

5

Status output

Status output return for AOK, SO1, SO2, SO3.

SORET

return

Isolated from power input return. for details, see

 

 

Figure 2-1.

6

Status output

Status output return for AOK, SO1, SO2, SO3.

SORET

return

Isolated from power input return. for details, see

 

 

Figure 2-1.

Table 3-6:Connector J3

3.6.2Connecting a Non-isolated Raven to an Isolating Power Transformer

Be sure to ground:

DC power common

Motor chassis

Amplifier heatsink

Do not ground the control common, which is internally connected to the power common. Grounding the control common will create a ground loop.

Page 18
Image 18
Elmo RAV-25/60, EXTRA IQ RAVEN manual 6Connector J3, Aok