Elo TouchSystems 1525L manual Property, Access, Description, cmdpendingLF, devstatusLF

Models: 1525L

1 181
Download 181 pages 49.02 Kb
Page 101
Image 101
cmd_pending<LF>

MagTek Device Drivers for Windows

Property

Access

 

Description

c_write

R

1 if the device can encode a magnetic card in either LoCo or HiCo;

 

 

2 if the device can encode a magnetic card in only the setting

 

 

indicated in wr_coer

 

c_wr_secure

R

0 if the device does not support secure mode;

 

 

1 if the device can switch between secure and non-secure mode

 

 

(see wr_secure);

 

 

 

2 if the device only operates in the secure mode.

capitalize

R/W

Set this to 0 to prevent the driver from capitalizing the data for the

 

 

read and write commands. The default value for this property is

 

 

1 (enable capitalization).

 

card_stat

R

Current card sensor status:

 

 

 

0 = not blocked, 1 = blocked (PPINSERT).

chk_account

R

Check account number from check (MICR).

chk_amount

R

Check amount from check (MICR).

chk_bankid

R

Bank ID number from the transit field (MICR).

chk_data

R

Output data string as received from MICR reader (MICR).

chk_format

R/W

Indicates the format of the check data. Set to 6500 by default. If

 

 

this property is modified by the application, the chk_xx properties

 

 

(except chk_data and chk_status) will be set to null. (MICR)

chk_mod10

R

Mod10 check digit from the transit field (MICR).

chk_number

R

Check number (MICR).

 

chk_routing

R

Routing number from the transit field (MICR).

chk_status

R

2-digit status code from the check just read (MICR).

chk_transit

R

Transit number from check (MICR).

cmd_pending

R

Command pending–indicates which command, if any, is pending.

 

 

If none is pending, the second argument will be null:

 

 

/get

cmd_pending<LF>

dblpinentry

R/W

Set to 1 to enable double PIN entry such as when requesting a new

 

 

PIN; set to 0 when verifying a customer’s PIN (IntelliPIN).

dev_status

R

Device status. 0 means device is connected and operational. Any

 

 

other value indicates a device-specific error. If the device fails to

 

 

respond, a null value is reported:

 

 

/get

dev_status<LF>

dev_version

R

Device version string. This value is read directly from the device,

 

 

if the device supports a version string. <CR> characters in the

 

 

string read from the device will be replaced with /. This property

 

 

will be useful in reporting operational problems to MagTek.

enable_cmc7

R/W

Set this property to 1 to enable CMC-7 characters decoding, 0 to

 

 

disable it. This is used for international checks; see MICR manual

 

 

for more information. (MICR)