1
Redundancy in Configurations 1-17
About the Rackmount Disk-Array Processor Enclosure
Redundancy in Configurations
Mirrored storage-system write caching requires:
Two SPs with equal memory of at least 128 Mbytes
Two power supplies
Two LCCs in the DPE and each DAE
Disks in slots 0:0 through 0:8
SPS (standby power supply) with a fully charged battery
The following table describes the DPEs high-availability
configurations.
These configurations provide more redundancy, and therefore a
higher degree of system availability. The drive fan packs and SP fan
pack provide redundant cooling for all the configurations listed
above.
0123456789
Database
drives for
LIC
(0 thru 2)
Vault
drives for
caching
(0 thru 8)
DPE Rackmount
Configuration SPs LCCs
Power
supplies
Disk
modules SPSs
Maximum - HA 2
2
2
2
2
2
3 or more
9 or more
0 (no write caching)
2 (high-availability write caching)