3
Removing an SP or an SP Filler Module 3-21
Servicing and Upgrading a DPE
2. Install the appropriate optical cable(s) on the SP’s optical GBIC
connector(s) as previously noted and as shown below.
Figure 3-14 Installing an Optical Cable on an SP
3. Remove and store the ESD wristband.
Removing an SP or an SP Filler ModuleCAUTION
!
Handle an SP gently and use an ESD wristband. Do not remove a
faulty SP until you have a replacement module or filler module
available.
SPs, GBICs, and memory modules are separate CRUs. New or
replacement SPs are shipped without memory modules or GBICs.
When a memory module and/or GBICs are ordered with the SP, they
will arrive with the SP; however, they will not be installed on the SP
B
A
Fibre optic cable
Cover
Optical GBIC
connector
Cover
A. Remove the protective covers
on each optical GBIC
connector and on each fibre
optic cable.
B. Plug the fibre optic cable into
Port A and/or Port B on the
SP.