Installing a DPE in a Cabinet 2-13
Installing a Rackmount DPE
11. Reinstall the drive fan pack on the back of the DPE.
You can install the drive fan pack in either horizontal position.
However, for a consistent image with DAEs, we recommend you
install it with the check light in the upper right corner, as shown
below.
Figure 2-8 Installing the Drive Fan Module
12. Attach the Fibre Channel cable from SP A and/or B Port to the
external environment) as shown next.
When working with optical cables, observe the following precautions:
Keep the covers on all optical cables and optical GBICs until
you are ready to insert the cables. The covers protect the cables
and connectors, and prevent foreign particles, such as dust,
from entering and affecting the connection.
Do not leave an unused (that is, dangling) cable, connected to
an SP port because it may cause excess noise on the loop.
A. Grasp the latches on the drive fan
module.
B. Squeeze the latches together and
gently push the module into the
enclosure until it clicks into place.
Check light