12.2.2Configuration

It is important that the 4 mA and the 20 mA levels are properly configured in order to obtain correct water level readings from the WLS. The distance “X” between the Tank Zero Level and the Water Zero Level has to be considered when configuring the WLS. “X” can be calculated from known tank distances as illustrated in Fig. 12-8.

Tank Reference point

 

Mark

 

 

 

version2.eps

 

20 mA

 

 

 

 

geometry

Tank Zero Level

 

Water Zero

 

 

 

4 mA

Level

wls_

 

 

 

 

Figure 12-8.

Tank geometry for the Water Level Sensor

The distance X can be calculated with the following formula:

X = (R-L1) - (L-L2).

X=distance between the Tank Zero Level and the Water Zero Level.

L=distance between Water Zero Level and mark on the upper part of the WLS.

R= Tank Reference Height. This is the distance between the Tank Reference Point and the Tank Zero Level.

L1=distance between the Tank Reference Point and the temperature sensor flange.

L2=distance between the mark on the top of the WLS and the temperature sensor flange.

12-6

Page 140
Image 140
Emerson 308014EN, Edition 4 installation manual 12-6, Tank geometry for the Water Level Sensor

308014EN, Edition 4 specifications

The Emerson Edition 4,308014EN is an innovative model that brings together cutting-edge technology and user-friendly features, catering to the needs of today's demanding environments. This state-of-the-art product is designed specifically for industrial applications, providing exceptional reliability and efficiency.

One of the standout features of the Emerson Edition is its advanced control system. It utilizes the latest algorithms to ensure precise monitoring and regulation, enhancing performance and reducing the likelihood of errors. This control system not only optimizes functionality but also enables seamless integration with existing infrastructure, making it a versatile choice for various industries.

In terms of design, the Emerson Edition 4,308014EN boasts a robust and durable construction, ensuring it can withstand the rigors of tough working conditions. Its rugged exterior is resistant to corrosion, dust, and moisture, which is particularly beneficial for applications in challenging environments such as chemical plants, oil and gas facilities, and manufacturing operations.

The device is equipped with intuitive user interfaces, which simplify operation and maintenance. It features a bright display that provides clear and concise information about system performance and status, allowing users to easily monitor operations at a glance. Additionally, it supports remote access functionality, enabling operators to manage and troubleshoot the system from a distance, thus improving efficiency and reducing downtime.

Incorporating the latest communication technologies, the Emerson Edition 4,308014EN supports various networking protocols, making it compatible with a wide range of devices and systems. This connectivity allows for real-time data exchange, further enhancing the ability to make informed decisions quickly.

Energy efficiency is another critical aspect of this model. The Emerson Edition is designed to minimize energy consumption without compromising performance, which not only lowers operational costs but also aligns with sustainability objectives. This focus on energy efficiency helps organizations contribute to environmental stewardship while maintaining high productivity levels.

Overall, the Emerson Edition 4,308014EN is a remarkable product that combines durability, advanced technology, and user-friendly features. Its capabilities make it an excellent choice for professionals seeking a reliable solution in demanding industrial applications. Whether for optimizing processes or ensuring smooth operation in challenging environments, the Emerson Edition delivers unparalleled performance and value.