Rosemount Tank Radar REX
Chapter 10 Mechanical Installation
10-32
Installation Manual
308014EN, Edition 4
May 2013
5Make sure that the O-ring is
properly seated all around the
cover and that it is pressed
down at the Hand Dip Plate.
6Close the lid and tighten the
locking screw.
7Place the Stand Bracket on the
desired side of the flange.
Attach the Stand bracket with
the two small screws. These
screws are used in order to
make sure that the Stand
Bracket is properly aligned to
the flange.
O-ring
Hand Dip
Plate
3950_3_O-ring.eps
Locking screw
3950_3_lockingscrew.eps
Stand Bracket
Two screws
3950_3_bracket.eps