System Management Interface Based on HPI-B (Centellis 4620) User’s Guide (6806800D85A)
Software Installation and Configuration Configuring HPI Clients
20
2.3.2 Configuring HPI Clients
Before running your client, you need to configure the multishelf library on the node where the
client is to run. The configuration has to be done in the following configuration file:
/opt/motorola/etc/bbs-hpib/bbs-hpibmultishelf.conf
Most of the entries should be left as they are. They have been set to values that are appropriate
for most operations. The only settings that need to be adapted are those which are related to
the HPI daemons that the multishelf library wishes to access. The following table shows the
expected syntax of the related entries.
Typically you will want to specify both HPI daemons in the shelf in the configuration file so that
your application can establish a connection with the second HPI daemon in case the connection
with the first HPI daemon fails.
The following table lists the IP addresses and ports of the HPI daemons in a Centellis 4620
shelf.
/opt/motorola/bin Contains precompiled example applications. They are controlled via
the command line and can easily be identified through the prefix "hpi"
in their names. Use the -h option to display supported command line
parameters.
/opt/motorola/etc/bb
s-hpib Contains configuration files used to configure HPI client libraries. See
for details.
Table 2-3 Overview of HPI-B Directories and Files on Node Blades (continued)
Directory Description
Table 2-4 Multishelf Library Configuration File - HPI Daemon Entries
Entry Description
[Shelf<Domain Name>] This indicates the start of the definition of an HPI daemon.
The chosen domain name appears as name of the Shelf
Management Resource and is used as Domain tag. See
Shelf Management Resource on page 32.
Daemon=<IP address of HPI
daemon> This is the IP address used to access an HPI daemon.
Port=<port number> This is the port number. The HPI daemon uses 4743 as
port.
Table 2-5 IP Addresses/Ports of HPI Daemons in a Centellis 4620 Shelf
Location of HPI Daemon IP Address Port
Left ATCA-F120 in a shelf 192.168.21.1 4743
Right ATCA-F120 in a shelf 192.168.22.2 4743