IPMI System Boot Options SupportUsing HPI-B

Table 4-12 Boot Option State

SaHpiCtrlStateT

Value

 

 

Type

SAHPI_CTRL_TYPE_OEM

 

 

StateUnion.Oem.Mid

MOTHPI_MANUFACTURER_ID_MOTOROLA

 

 

StateUnion.Oem.BodyLength

Get operations:

 

When input parameter: 3

 

When output parameter: Total length of the response data -

 

2

 

Set operations:

 

Total length of the request data

 

 

StateUnion.Oem.Body

Get operations:

 

When input parameter:

 

Byte 0: Parameter selector

 

Byte 1: Set selector

 

Byte 2: Block selector

 

When output parameter:

 

Response data from the GetSystemBootOptions IPMI

 

command without the first two bytes

 

Set operations:

 

Request data for the IPMI SetSystemBootOptionss

 

command

 

 

Example: on most Emerson blades, the BIOS software is stored twice on a flash device, BIOS bank 1 and BIOS bank 2. The bank to boot from can be selected with the System Boot Options Control.

You have to select parameter 96 with the Boot Option Select Control and then set the BIOS 1

(0) or BIOS 2 (1) with the Boot Option Control.

The following example shows how to set BIOS 2 for a resource with the ID 120 using an example program which is delivered together with the HP-B development package:

hpibootoptions -r 120 96 1

The example program hpibootoptions, which is available in the base RPM package, shows how an option can be set or got.

System Management Interface Based on HPI-B (Centellis 4620) User’s Guide (6806800D85A)