MODEL | SPECIFICATIONS |
SPECIFICATIONS -GENERAL
Case: Cast aluminum containing less than 6% magnesium.
NEMA 4X (IP65), NEMA 7
Dimensions: 6.3 in. x 6.9 in. x 6.4 in. (160 mm x 175 mm x 161 mm); diameter 6.1 in (155 mm)
Conduit Openings: 3/4 in. FNPT
Reference Impedance: Transmitter accepts high impedance (i.e. glass) reference electrodes as well as low impedance (i.e.
Response Time: Display reaches 95% of final reading within 10 seconds.
Temperature Sensors: The following RTDs can be used with the Model
3 and 4 wire Pt 100 RTDs
3 and 4 wire Pt 1000 RTDs
Transmitter can also be used with
Temperature Range: 5°F to 248°F
Local Display: Two line LCD; first line shows process variable (pH or ORP), second line shows temperature and output sig- nal. When triggered, fault and warning messages alternate with temperature and output readings.
Process variable: 7 segment LCD, 0.8 in. (20 mm) high
Temperature/output: 7 segment LCD, 0.3 in. (7 mm) high
Display board can be rotated 90 degrees clockwise or coun- terclockwise.
During calibration and programming, messages and prompts appear in the temperature/output area.
Power Supply and Load Requirements: A power supply volt- age of
Security: User selected security code prevents accidental changes to program settings.
Ambient Temperature:
Relative Humidity: 0 to 95% (with covers sealed)
Storage Temperature:
EMI/RFI: Meets the requirements of
Sira MC070112/00
Hazardous Area Classification:
Intrinsic Safety:
Class I, II, III, Div. 1
Groups
T4 Tamb = 70°C
| Exia Entity | ||
| Class I, Groups | ||
| Class II, Groups | ||
| Class III | ||
| T4 | Tamb = 70°C | |
| ATEX | 0600 II 1 G | |
| Baseefa02ATEX1284 | ||
2 | EEx | ia IIC T4 | |
Tamb = | |||
|
Class I, Div. 2, Groups
Dust Ignition Proof
Class II & III, Div. 1, Groups
NEMA 4X Enclosure
Class I, Div. 2, Groups
Suitable for Class II, Div. 2, Groups
T4 Tamb = 70°C
Class I, Div. 1, Groups
Class II, Div. 1, Groups
Class III, Div. 1
Class I, Groups
Class II, Groups
Class III
Tamb = 65°C max
SPECIFICATIONS - pH
pH Input Range: 0 to 14 pH
Temperature Input Range: 5°F to 248°F
Accuracy at 25°C: ±0.01 pH
Repeatability at 25°C: ±0.01 pH
Resolution: 0.01 pH and 0.1°C or °F
Stability at 25°C: 0.25% per year
Diagnostics: The internal diagnostics can detect:
Calibration Error | Low Temperature Error |
High Temperature Error | Sensor Failure |
Line Failure | CPU Failure |
ROM Failure | Input Warning |
Glass Failure | Glass Warning |
Reference Failure | Reference Warning |
Once one of the above is diagnosed, the LCD will display a message describing the failure/default detected.
Temperature Compensation: Automatic or manual between 5°F to 248°F
Solution Temperature Compensation: Transmitter will convert pH measured at any temperature to the pH at 25°C. Temperature coefficient is programmable between
Calibration: Automatic
SPECIFICATIONS - ORP
ORP Input Range:
Temperature Input Range: 5°F to 248°F
Output Scale Expansion: Continuously expandable between - 1400 and 1400 mV
Accuracy at 25°C: ±1 mV
Repeatability at 25°C: ±1 mV
Resolution: 1 mV and 0.1°C or °F
Stability at 25°C: 0.25% per year