Thin Web Server

 

 

Troubleshooting

 

 

 

 

 

Symptom

Possible

Possible

Action

Prevention

Problem

Cause

 

 

 

13. Server setup

Corrupted

– TSSP & TWS program

Same as item 4

Same as item 4

program cannot

TWS

version mismatch.

 

 

upload /

configuration

 

 

 

download

file.

 

 

 

configuration.

 

 

 

 

Receiving an

 

 

 

 

error message

 

 

 

 

after upload /

 

 

 

 

download.

 

 

 

 

14. Serial Modbus

Modbus

– TWS is not serially connected

– Make sure to use the correct serial adapter to connect the

– Follow this Installation

communication

master cannot

properly to the Modbus

Modbus master to the TWS.

Manual for how to

is not working

communicate

master.

– Only COM2 can be used for serial Modbus

connect and implement

properly.

with TWS.

– TSSP was not configured for

communication.

Modbus communication

 

 

serial Modbus

– Make sure to enable and set up serial communication to the

in the TWS.

 

 

communication.

TWS properly.

– Only use TWS Modbus

 

 

– Incorrect serial cable adapter

– Make sure to use only the register maps for TWS serial

communicaton register

 

 

used for this application.

Modbus communication.

maps in designing GUI

 

 

– Incorrect registers used by the

 

applicaton that will

 

 

Modbus master.

 

communicate to ASCO

 

 

 

 

device through the

 

 

 

 

TWS.

 

 

 

 

 

15. TCP/IP open

Modbus

– TWS was not configured for

– Make sure to enable and set up TCP/IP Modbus

– Follow this Installation

Modbus

master cannot

TCP/IP Modbus

communication to the TWS properly through TSSP.

Manual for how to

communication

communicate

communication.

– Make sure to use only the register maps for TWS TCP/IP

install the TWS and use

is not working

with TWS.

– Incorrect registers and

Open Modbus communication.

the TSSP.

properly.

 

addressing scheme used by

– TCP/IP Modbus communication of the TWS only renders

– Only use TWS Modbus

 

 

the Modbus master.

data from serial devices connected to its COM3 & COM4

communication register

 

 

 

ports. TWS does not render data from remote 72Es.

maps in designing GUI

 

 

 

 

application that will

 

 

 

 

communicate to ASCO

 

 

 

 

device throught the

 

 

 

 

TWS.

16. Needed to reset

 

 

– Run your server setup program again, connect to the TWS.

 

alarm logs.

 

 

Go to Utilities, Server File Management and delete

 

 

 

 

the file C:\alarm.bin. Refer to page 5-1.

 

 

 

 

 

 

Page 38
Image 38
Emerson 5500 SERIES, A5510 installation manual Go to Utilities , Server File Management and delete

5500 SERIES, A5510 specifications

The Emerson 5500 Series, specifically the A5510 model, is a cutting-edge solution in the field of measurement and control, renowned for its reliability and precision in industrial applications. This versatile device is primarily used in various sectors, including oil and gas, water treatment, and manufacturing processes, where accurate monitoring and control of parameters such as pressure, temperature, and flow are critical.

One of the main features of the Emerson A5510 is its advanced digital communication capabilities. It supports various industrial protocols such as HART, Modbus, and Profibus, allowing for seamless integration with existing control systems. This connectivity ensures real-time data exchange, enabling operators to make informed decisions quickly and effectively.

The A5510 is equipped with robust diagnostic tools that enhance operational efficiency. Users benefit from features like predictive maintenance alerts and comprehensive data logging, which facilitate troubleshooting and help prevent unexpected failures. This proactive approach to maintenance not only reduces downtime but also extends the device's lifespan.

The device boasts a highly intuitive user interface, which simplifies the configuration and calibration process. Operators can easily navigate through its menu to customize settings according to specific application requirements. This user-centric design minimizes training time and helps users maximize the device's capabilities.

In terms of construction, the Emerson A5510 is designed for durability in harsh environments. It is built with high-grade materials that provide excellent resistance to corrosion and extreme temperatures. This robustness ensures that the device remains operational even in challenging industrial settings, maintaining accuracy and reliability.

The A5510 also features advanced signal processing technology that enhances measurement fidelity. It effectively filters out noise and minimizes the impact of environmental variables, ensuring that the readings are both stable and accurate. This is particularly beneficial in applications where precision is paramount.

Additionally, Emerson emphasizes sustainability and energy efficiency in the design of the 5500 Series. The A5510 is engineered to consume minimal power while delivering top-notch performance, aligning with the industry's growing focus on reducing energy consumption and environmental impact.

In summary, the Emerson 5500 Series A5510 is a sophisticated measurement and control device that combines advanced technology, durability, and user-friendly features. Its digital communication capabilities, robust diagnostics, and energy-efficient design make it an ideal choice for businesses seeking to optimize their operations and enhance their monitoring processes. With the A5510, Emerson continues to set the standard for innovation and reliability in industrial measurement solutions.