Figure 10 LOOKING UP INTO SWITCH HOUSING ASSEMBLY

16.Position the lower trim assembly on the upper cover trim so that the tabs on the lower trim assembly slide into the slots in the upper cover trim (Figure 11). Then securely install four 8-32 x 1/2” screws (supplied).

UPPER Electrical Requirements COVER TRIM

How to Hang Your SLOT

8-32 x 3/8" SCREW (4)

Manual background LOWER TRIM ASSEMBLY

Figure 11

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

How to Hang Your

Ceiling Fan

!WARNING

The fan must be hung with at least 7' of clearance from floor to blades (Figure 12).

CEILING

AT LEAST

7'

Figure 12

FLOOR

!WARNING

The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked acceptable for fan support, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

1.Securely attach the hanger bracket to the outlet box using the two screws supplied with the outlet box. (Figure 13).

!WARNING

Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.

OUTLET

Manual background BOX

TWO SCREWS

 

SUPPLIED WITH

HANGER

OUTLET BOX

 

BRACKET

Figure 13

TAB

 

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with national and local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

2.Carefully lift the fan and seat the hanger ball/ downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 14). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 13).

!WARNING

Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.