NOTE: CEILING COVER, |
SUPPLY WIRES AND |
EMERSON FAN CONTROL
FAN WIRES OMITTED | OUTLET | |
BOX | ||
FOR CLARITY. | ||
|
HANGER |
BRACKET |
LISTED OUTLET BOX
BLACK FAN WIRE
BLACKRED
GREEN WIRE (GROUND)
FROM HANGER
BRACKET
WHITE
GROUND
WIRE
LIGHT | BLACK |
CONTROL | |
| (HOT) |
| TO 120 |
| VOLT |
| SUPPLY |
WHT. |
|
Figure 28 | HANGER BALL/ |
DOWNROD ASSEMBLY |
!WARNING
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and the hanger bracket.
!WARNING
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. NOTE: If you are not sure if the outlet box is ground- ed, contact a licensed electrician for advice, as it must be grounded for safe operation.
NOTE: If you are installing a SR330 Remote Control or a SW350 Wall Control to operate the fan and light, refer to the installation instructions and wiring diagrams shown in Section A of this Owner’s Manual.
22.For a wall control installation you will need a
a.Connect the green grounding lead from the hanger ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or a wire with green colored insulation). Securely con- nect wires with wire connector supplied.
b.Securely connect the white wire from the downrod to the supply white (neutral) wire using wire connector supplied. Securely con- nect the black wire from the downrod to the supply black (hot) wire using wire connector supplied.
c.Cut terminal off of the yellow lead wire and strip insulation 1/2” from end of wire.
d.Securely connect the blue wire and yellow wire from the downrod to the supply red (hot) wire using wire connector (supplied). After connec- tions have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black, blue and yellow leads on the other side of the outlet box.
BLUE | GROUND | GROUND |
|
| |
GREEN WIRE (GROUND) | THREE - CONDUCTOR CABLE | |
WITH GROUND BETWEEN | ||
FROM HANGER BALL | CEILING AND WALL OUTLET | |
LISTED WIRE CONNECTOR (4) | BOXES |
|
|
|
Figure 29
23.To complete the ceiling fan assembly, proceed to the “FINAL ASSEMBLY” section.
!WARNING
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
FINAL ASSEMBLY
1.Screw the two
2.Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 30).
3.Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs (supplied). (Figure 30.) Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the pipe.
| CEILING COVER |
LOCKWASHERS (2) | |
| |
THREADED |
|
STUD |
|
KNURLED KNOB |
Figure 30
!WARNING
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.
4.Screw in three
11