5.Using wiring connectors (supplied), connect the white, red, blue, brown, and yellow wires from the downrod to the white, red, blue, brown and yellow wires of the ceiling fan (Figure 4). Wires must be connected color-to-color.

SW375 RECEIVER

WHITE WIRE

LEADS TO BE

POSITIONED IN

SLOT IN MOTOR

COUPLING

SETSCREW

DOWNROD

HAIRPIN

CLIP

MOTOR COUPLING

YELLOW WIRE TO YELLOW WIRE

BLUE WIRE TO

BLUE WIRE

BLACK WIRE

WHITE WIRE

RECEIVER

CONNECTOR

WIRING HARNESS

CONNECTOR

BLACK WIRE

BLACK

 

WIRE

DOWNROD

 

LISTED GENERAL USE ON/OFF WALL SWITCH (MUST BE

USED WITH SR330

REMOTE CONTROL)

WHITE

WIRE

CLEVIS PIN

DOWNROD

BLACK WIRE (NOT USED)

FAN HOUSING

 

 

 

TO

 

120V SUPPLY

RED WIRE

BLACK

WHITE

TO RED WIRE

 

 

 

BROWN WIRE

 

 

 

TO BROWN WIRE

 

 

SW350

BLUE WIRE

 

 

WALL

 

 

CONTROL

TO BLUE WIRE

 

 

 

 

 

 

 

WHITE WIRE

 

 

 

TO WHITE WIRE

BLACK

 

YELLOW WIRE

 

 

 

 

TO YELLOW WIRE

TO

120V SUPPLY

HAIRPIN CLIP

CLEVIS PIN

CLEVIS PIN

MOTOR COUPLING

Figure 5

LIGHT FIXTURE

FAN BLADES REMOVED

FOR CLARITY

Figure 4

6.Fold all wires from the downrod into the slot in the motor coupling, slide the downrod down the wires and seat the downrod in the motor coupling. All wires and wire connectors should be placed through the motor coupling slot beneath the down- rod (See Figure 5).

7.Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip. The clevis pin must go through the holes in the motor coupling and the holes in the downrod (Figure 5). Push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose.

!WARNING

It is critical that the clevis pin in the motor coupling is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.

8.Install the setscrew (supplied in the loose parts bag) in the motor coupling and tighten using the 5/32” setscrew wrench (supplied) (Figure 5).

NOTE: Make sure the unused black motor lead is capped with a wire connector. Make sure all wire connectors are completely inside motor coupling cover and not pinched between the motor coupling cover and motor.

9.Screw two 1” threaded studs (supplied) into the motor (Figure 6). Leave approximately 7/8” of the stud extending above the motor. Slide the motor cover over the downrod and rotate the cover until the threaded studs protrude; install two knurled knobs (supplied) to secure the cover.

KNURLED KNOB

MOTOR

COUPLING

COVER

WIRE

CONNECTORS

1" THREADED STUD

MOTOR

7/8"

 

Figure 6

10.Position the ceiling cover over the downrod. Be sure the cover is oriented correctly, with the large opening at the top (Figure 7).

5

Page 5
Image 5
Emerson CF2500S01, CF2500HTW01, CF2500TG01, CF2500OB01 owner manual Knurled Knob Motor Coupling Cover Wire Connectors