Emerson CF943 Installation of Wall Control, SINGLE-POLEINSTALLATION Figure, Wayinstallation

Models: CF943

1 20
Download 20 pages 18.49 Kb
Page 6
Image 6
Installation of Wall Control
2. At all wall box locations remove faceplates and screws from existing switches. Pull switches out from wall boxes and determine which wall box contains the “hot” lead and which wall box contains the “load” wire. Also, identify traveler wires which are common to both wall boxes. Disconnect wires from existing switches only. Do not attempt to disconnect any wires not already connected to existing switches.

BP7335 Palazzo 1/9/07 9:05 AM Page 6

Installation of Wall Control

SINGLE-POLE INSTALLATION (Figure 2)

HOT

BLK

FAN/LIGHT

 

WALL CONTROL

 

 

EMERSON

BLACK

 

 

 

BLACK

LOAD

NEUTRAL

 

 

GROUND

 

 

 

REMOTE CONTROL

 

 

SINGLE-POLE INSTALLATION (Figure 2)3-WAY INSTALLATION 5. Connect the other black wire of wall control to the “load” (black) wire in wall box. Securely connect wires with wire connector supplied.

6. Screw wall control into wall box and install decorator style faceplate (included). Leave wall control in “OFF” mode until fan installation is completed.

7. Refer to page 7 to complete the ceiling fan installation.

RECEIVER LOCATED

WITHIN THE CEILING

COVER

Figure 2

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse or circuit breaker box before wiring.

HI

 

 

 

LIGHT

 

MED

 

 

LOW

 

 

FAN OFF

 

 

EMERSON

®

 

OFF

ON

 

Figure 3

BLK

T

 

 

HOT

 

 

 

 

 

 

 

 

 

 

 

 

O

 

 

 

 

 

 

 

 

1

2

0V

 

 

O

 

E

 

 

 

 

 

 

 

 

AC

S

C

 

 

 

 

 

UR

 

T

 

 

 

O

 

 

BLACK

LOAD

 

 

 

 

D

 

 

 

N

 

 

 

U

 

G

R

O

 

 

FAN/LIGHT

 

 

 

 

WALL

WALL

 

 

CONTROL

 

 

BOX

All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

3-WAY INSTALLATION

(On fan controlled by two different wall controls) (See Figures 4 and 5.)

Manual backgroundManual background 1. Disconnect power at circuit breaker or remove fuse.

Manual backgroundManual background 1. Disconnect power at circuit breaker or Manual background remove fuse.

Manual backgroundManual background 2. Remove faceplate and screws from existing wall switch. Pull switch out from the wall box. Determine the “hot” wire and the “load” wire and disconnect these wires from switch. Do not attempt to disconnect any wires not already connected to existing switch.

Manual backgroundManual background 3. Before installing wall control, place wall control in “OFF” mode by pushing “ON/OFF” switch to the “OFF” position. 3.

!WARNING

Before installing wall control, place wall control in “OFF” mode by pushing “ON/OFF” switch to the “OFF” position.

Do not connect any neutral (white) wire to this control. Incorrect wiring will damage this control.

Manual backgroundManual background 4. Connect one black wire of wall control to the “hot” wire in the wall box. Securely connect wires with wire connectors supplied (Figure 3).

!WARNING

Do not connect any neutral (white) wire to this control. Incorrect wiring will damage this control.

6

Page 6
Image 6
Emerson CF943 owner manual Installation of Wall Control, SINGLE-POLEINSTALLATION Figure, Wayinstallation