SW105

TO

RECEIVER

110V

BLACK

SUPPLY

SUPPLY

 

WHITE RECEIVER WIRE

WHITE SUPPLY WIRE

BLACK RECEIVER WIRE

BLACK/WHITE RECEIVER

BLUE RECEIVER WIRE

WHITE FAN WIRE

BLUE FAN WIRE

 

BLACK FAN WIRE

YELLOW RECEIVER

 

WIRE

 

DO NOT USE

DOWNROD

 

Figure 15

WARNING

Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.

4.Carefully turn the wires upward and insert them up through the open side of the hanger bracket and into the outlet box. Push the green and white wires into one side of the outlet box; push the black, blue and yellow wires into the other side of the outlet box.

OUTLET BOX

HANGER

BRACKET

RECEIVER

CEILING

COVER

Figure 16

7.Secure the ceiling cover in place by sliding lockwashers (supplied) over the threaded studs and installing the two knurled knobs (supplied). (Figure 17.) Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch.

1-1/4"

CEILING

THREADED

COVER

STUD

 

 

LOCKWASHER

KNURLED KNOB

Figure 17

WARNING

To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.

5.Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 17).

6.Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 17).

9

Page 9
Image 9
Emerson CF980MBX 00, CF980MAB 00 warranty Black