Emerson CMF200A installation manual Wrapping the shield drain wires

Models: CMF200A

1 26
Download 26 pages 54.18 Kb
Page 19
Image 19

Figure 14 Micro Motion cable gland and heat shrink

3/4 in

(19 mm)

Gland nut

Gland clamping

insert

 

7/8 in

(22 mm)

Shielded heat shrink

Wiring

4 1/2 in

(114 mm)

7/8 in

(22 mm)

Gland body

4.For connection at the core processor housing, prepare shielded cable as follows (for armored cable, omit steps d, e, f, and g):

a.Strip 4 1/2 inches (114 mm) of cable jacket.

b.Remove the clear wrap that is inside the cable jacket, and remove the filler material between the wires.

c.Remove the foil shield that is around the insulated wires, leaving 3/4 inch (19 mm) of foil or braid and drain wires exposed, and separate the wires.

d.Wrap the shield drain wire(s) around the exposed foil twice. Cut off the excess wire.

Figure 15 Wrapping the shield drain wires

e.Place the shielded heat shrink over the exposed shield drain wire(s). The tubing should completely cover the drain wires.

f.Without burning the cable, apply heat (250 °F or 120 °C) to shrink the tubing.