Softing Linking Device –

Manual for Configuration, Installation and Maintenance

Hardware Installation

Stahl. You will find this manual on the CD-ROM or on the internet web page http://www.r- stahl.com

2.6 FF H1 fieldbus connection

The fieldbus terminals are mounted in 4 sets of three terminals for the positive and negative conductors and a shield (FF1 – FF4). Although the Linking Device is not polarity sensitive, other components in the segment such as junction blocks may require correct polarity.

With 3-pole terminal blocks, up to 4 separate fieldbus segments can be connected. The FF- H1 interfaces comply with type 114 of the FF physical layer profile, which is characterized by

standard power signalling and voltage mode

separately powered operation (galvanically isolated) no intrinsic safety

the fieldbus cables +/- can be interchanged.

wire diameter: 0.14 - 1.5 mm2, AWG 28-16

replacement parts for the terminal block can be obtained from Phoenix-Contact (http://www.phoenixcontact.com/) as part type MC 1,5/3-STF-3,81 BK AU.

+

-

Fig 2.6-1 Pin assignment 3-pole terminal block for FF H1 Connections

2.7 FIM-110 FF - The pre-wired Installation of the FG-110 FF

The FIM-110 FF has an IP-65 housing.

The upper cover provides access to single parts like

the Linking Device FG-110 FF,

the RS-232 / RS-485 converter,

the fieldbus power conditioners/terminators,

the power supply board and ground terminals.

The enclosure cover provides access to the terminal blocks. To open either cover of the enclosure, use a ¼ inch blade screwdriver to remove the appropriate screw on the unhinged side of the enclosure

The Linking Device is intended for mounting in a control cabinet. One of the favorite possibilities is the FIM (SOFTING Foundation Fieldbus Interface Module FIM 110)

V1.31

page 11 of 85

Page 11
Image 11
Emerson manual FF H1 fieldbus connection, FIM-110 FF The pre-wired Installation of the FG-110 FF

FG-110 specifications

The Emerson FG-110 is a versatile and advanced fire and gas detection system designed for industrial applications. With increasing safety and regulatory standards in industries such as oil and gas, chemical processing, and manufacturing, the FG-110 provides a reliable solution for detecting early signs of fire and gas leaks, ensuring the protection of personnel, assets, and the environment.

One of the key features of the Emerson FG-110 is its robust detection capabilities. It is equipped with a variety of sensors for detecting different types of gases, including combustible gases, toxic gases, and oxygen levels. This multi-sensitivity approach allows for enhanced safety in environments where various hazardous substances may be present. The sensors are designed for high accuracy and fast response times, ensuring that any potential issues are detected swiftly before they escalate into more serious incidents.

The Emerson FG-110 utilizes advanced signal processing technologies. This includes sophisticated algorithms that filter out false alarms, providing operators and safety personnel with reliable notifications. The system's ability to distinguish between genuine threats and harmless environmental changes is crucial in high-stakes environments where false alarms can lead to unnecessary disruptions and safety concerns.

One of the standout characteristics of the FG-110 is its modular design, allowing for flexible configurations tailored to specific site requirements. Users can easily integrate additional sensors or modules as their needs evolve or as they expand their facility. This scalability makes it an ideal choice for both new installations and retrofitting existing systems.

In terms of communications, the Emerson FG-110 supports various protocols, enabling seamless integration with existing safety management systems and centralized control rooms. This connectivity enhances real-time monitoring and data analysis, helping safety teams make informed decisions efficiently.

Built with durability in mind, the Emerson FG-110 meets rigorous industrial standards. Its rugged casing and resistance to harsh environmental conditions ensure long-lasting performance, which is essential for operations in environments exposed to extreme temperatures, vibrations, or corrosive substances.

In summary, the Emerson FG-110 fire and gas detection system combines advanced sensor technologies, reliable performance, and modular design to deliver a comprehensive safety solution for industrial applications. With its focus on accuracy, flexibility, and integration, the FG-110 stands out as a robust tool in maintaining safety and preventing hazards in complex industrial environments.